Micro immuno supported liquid membrane (mu-ISLM) extraction
(2005) 8th International Conference on Miniaturized Systems for Chemistry and Life Sciences p.512-514- Abstract
- A mu-ISLM (micro Immuno Supported Liquid Membrane) extraction system coupled in a sequential injection analysis (SIA) configuration, capable of simultaneous sample cleanup and enrichment was developed. The capacity of the extraction channels - donor and acceptor, respectively - were reduced from originally 10 to 1.65 mu L. The acceptor channel surface was covered with a gold layer enabling immobilisation of antibodies via an alkanthiol self-assembled monolayer. The mu-ISLM-SIA system resulted in very high extraction efficiency and enrichment factor (Extraction efficiency (E): 136%; Enrichment factor (E-e): 544) and a subsequent low detection limit for the model analyte simazine of 0.1 ng/L.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1406274
- author
- Tudorache, Madalina LU ; Norberg, J and Emnéus, Jenny LU
- organization
- publishing date
- 2005
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- extraction, simazine, supported liquid membrane, enrichment
- host publication
- Micro Total Analysis Systems 2004, Vol 1
- issue
- 296
- pages
- 512 - 514
- publisher
- Springer
- conference name
- 8th International Conference on Miniaturized Systems for Chemistry and Life Sciences
- conference location
- Malmo, Sweden
- conference dates
- 2004-09-26 - 2004-09-30
- external identifiers
-
- wos:000228997000172
- ISSN
- 0260-6291
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- e694ebba-a44a-4fd5-86a7-b6012b92d1a7 (old id 1406274)
- date added to LUP
- 2016-04-01 17:08:48
- date last changed
- 2024-07-02 13:21:06
@inproceedings{e694ebba-a44a-4fd5-86a7-b6012b92d1a7, abstract = {{A mu-ISLM (micro Immuno Supported Liquid Membrane) extraction system coupled in a sequential injection analysis (SIA) configuration, capable of simultaneous sample cleanup and enrichment was developed. The capacity of the extraction channels - donor and acceptor, respectively - were reduced from originally 10 to 1.65 mu L. The acceptor channel surface was covered with a gold layer enabling immobilisation of antibodies via an alkanthiol self-assembled monolayer. The mu-ISLM-SIA system resulted in very high extraction efficiency and enrichment factor (Extraction efficiency (E): 136%; Enrichment factor (E-e): 544) and a subsequent low detection limit for the model analyte simazine of 0.1 ng/L.}}, author = {{Tudorache, Madalina and Norberg, J and Emnéus, Jenny}}, booktitle = {{Micro Total Analysis Systems 2004, Vol 1}}, issn = {{0260-6291}}, keywords = {{extraction; simazine; supported liquid membrane; enrichment}}, language = {{eng}}, number = {{296}}, pages = {{512--514}}, publisher = {{Springer}}, title = {{Micro immuno supported liquid membrane (mu-ISLM) extraction}}, year = {{2005}}, }