Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Visibility of current and shot noise in electrical Mach-Zehnder and Hanbury Brown Twiss interferometers

Chung, VSW ; Samuelsson, Peter LU and Buttiker, M (2005) In Physical Review B (Condensed Matter and Materials Physics) 72(12).
Abstract
We investigate the visibility of the current and shot-noise correlations of electrical analogs of the optical Mach-Zehnder interferometer and the Hanbury Brown Twiss interferometer. The electrical analogs are discussed in conductors subject to high magnetic fields where electron motion is along edge states. The transport quantities are modulated with the help of an Aharonov-Bohm flux. We discuss the conductance (current) visibility and shot noise visibility as a function of temperature and applied voltage. Dephasing is introduced with the help of fictitious voltage probes. Comparison of these two interferometers is of interest since the Mach-Zehnder interferometer is an amplitude (single-particle) interferometer, whereas the Hanbury Brown... (More)
We investigate the visibility of the current and shot-noise correlations of electrical analogs of the optical Mach-Zehnder interferometer and the Hanbury Brown Twiss interferometer. The electrical analogs are discussed in conductors subject to high magnetic fields where electron motion is along edge states. The transport quantities are modulated with the help of an Aharonov-Bohm flux. We discuss the conductance (current) visibility and shot noise visibility as a function of temperature and applied voltage. Dephasing is introduced with the help of fictitious voltage probes. Comparison of these two interferometers is of interest since the Mach-Zehnder interferometer is an amplitude (single-particle) interferometer, whereas the Hanbury Brown Twiss interferometer is an intensity (two-particle) interferometer. A direct comparison is only possible for the shot noise of the two interferometers. We find that the visibility of shot noise correlations of the Hanbury Brown Twiss interferometer as a function of temperature, voltage or dephasing, is qualitatively similar to the visibility of the first harmonic of the shot noise correlation of the Mach-Zehnder interferometer. In contrast, the second harmonic of the shot noise visibility of the Mach-Zehnder interferometer decreases much more rapidly with increasing temperature, voltage or dephasing rate. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Physical Review B (Condensed Matter and Materials Physics)
volume
72
issue
12
publisher
American Physical Society
external identifiers
  • wos:000232229400086
  • scopus:29744451141
ISSN
1098-0121
DOI
10.1103/PhysRevB.72.125320
language
English
LU publication?
yes
id
eed664e0-9962-4143-90b4-feaed7f1abaa (old id 223033)
date added to LUP
2016-04-01 15:39:26
date last changed
2022-03-07 00:46:32
@article{eed664e0-9962-4143-90b4-feaed7f1abaa,
  abstract     = {{We investigate the visibility of the current and shot-noise correlations of electrical analogs of the optical Mach-Zehnder interferometer and the Hanbury Brown Twiss interferometer. The electrical analogs are discussed in conductors subject to high magnetic fields where electron motion is along edge states. The transport quantities are modulated with the help of an Aharonov-Bohm flux. We discuss the conductance (current) visibility and shot noise visibility as a function of temperature and applied voltage. Dephasing is introduced with the help of fictitious voltage probes. Comparison of these two interferometers is of interest since the Mach-Zehnder interferometer is an amplitude (single-particle) interferometer, whereas the Hanbury Brown Twiss interferometer is an intensity (two-particle) interferometer. A direct comparison is only possible for the shot noise of the two interferometers. We find that the visibility of shot noise correlations of the Hanbury Brown Twiss interferometer as a function of temperature, voltage or dephasing, is qualitatively similar to the visibility of the first harmonic of the shot noise correlation of the Mach-Zehnder interferometer. In contrast, the second harmonic of the shot noise visibility of the Mach-Zehnder interferometer decreases much more rapidly with increasing temperature, voltage or dephasing rate.}},
  author       = {{Chung, VSW and Samuelsson, Peter and Buttiker, M}},
  issn         = {{1098-0121}},
  language     = {{eng}},
  number       = {{12}},
  publisher    = {{American Physical Society}},
  series       = {{Physical Review B (Condensed Matter and Materials Physics)}},
  title        = {{Visibility of current and shot noise in electrical Mach-Zehnder and Hanbury Brown Twiss interferometers}},
  url          = {{http://dx.doi.org/10.1103/PhysRevB.72.125320}},
  doi          = {{10.1103/PhysRevB.72.125320}},
  volume       = {{72}},
  year         = {{2005}},
}