Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Multispectral Tissue Characterization With Time-resolved Detection of Diffusely Scattered White-light

Andersson-Engels, Stefan LU ; Berg, R ; Persson, A and Svanberg, Sune LU (1993) In Optics Letters 18(20). p.1697-1699
Abstract
A novel technique for the noninvasive measurement of tissue optical properties simultaneously at all visible and near-infrared wavelengths is presented. The technique is based on.the time-resolved detection of multicolor diffusely scattered light. Short pulses of white light are/produced by using self-phase modulation by focusing the light from a short-pulsed high-power laser into a cuvette filled with water. After spectral dispersion in a polychromator and temporal dispersion in a streak tube, a two-dimensional CCD camera was used as a detector, with one dimension used for time resolution and the other one for wavelength separation.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Optics Letters
volume
18
issue
20
pages
1697 - 1699
publisher
Optical Society of America
external identifiers
  • scopus:0027671561
ISSN
0146-9592
DOI
10.1364/OL.18.001697
language
English
LU publication?
yes
id
fc8357e6-d768-4cfe-80b0-a28227f1d149 (old id 2257257)
date added to LUP
2016-04-04 09:37:38
date last changed
2021-09-19 05:11:16
@article{fc8357e6-d768-4cfe-80b0-a28227f1d149,
  abstract     = {{A novel technique for the noninvasive measurement of tissue optical properties simultaneously at all visible and near-infrared wavelengths is presented. The technique is based on.the time-resolved detection of multicolor diffusely scattered light. Short pulses of white light are/produced by using self-phase modulation by focusing the light from a short-pulsed high-power laser into a cuvette filled with water. After spectral dispersion in a polychromator and temporal dispersion in a streak tube, a two-dimensional CCD camera was used as a detector, with one dimension used for time resolution and the other one for wavelength separation.}},
  author       = {{Andersson-Engels, Stefan and Berg, R and Persson, A and Svanberg, Sune}},
  issn         = {{0146-9592}},
  language     = {{eng}},
  number       = {{20}},
  pages        = {{1697--1699}},
  publisher    = {{Optical Society of America}},
  series       = {{Optics Letters}},
  title        = {{Multispectral Tissue Characterization With Time-resolved Detection of Diffusely Scattered White-light}},
  url          = {{https://lup.lub.lu.se/search/files/5374489/2296999.pdf}},
  doi          = {{10.1364/OL.18.001697}},
  volume       = {{18}},
  year         = {{1993}},
}