The new septum magnets
(2005) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 547(2-3). p.686-689- Abstract
- In an earlier paper we reported on a new septum magnet design with a magnetic flux filter [1]. Now the first septum magnet is in operation as in injection septum magnet for the MAX I storage ring. We dcscribe the actual mechanical construction and the field measurements of the new magnets. The fine Structure of the septum nose needed several trials in the construction until we found the final solution. The measured residual stray fields in the ring tube are even smaller than was expected from the model calculations.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/229542
- author
- Lindgren, Lars-Johan LU and Anderberg, B
- organization
- publishing date
- 2005
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- storage ring, septum, accelerator, magnet, injection
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 547
- issue
- 2-3
- pages
- 686 - 689
- publisher
- Elsevier
- external identifiers
-
- wos:000231001800042
- scopus:22344453285
- ISSN
- 0167-5087
- DOI
- 10.1016/j.nima.2005.04.006
- language
- English
- LU publication?
- yes
- id
- 93248865-9932-4bcf-ac7d-52218df208a3 (old id 229542)
- date added to LUP
- 2016-04-01 15:59:48
- date last changed
- 2022-01-28 08:33:27
@article{93248865-9932-4bcf-ac7d-52218df208a3, abstract = {{In an earlier paper we reported on a new septum magnet design with a magnetic flux filter [1]. Now the first septum magnet is in operation as in injection septum magnet for the MAX I storage ring. We dcscribe the actual mechanical construction and the field measurements of the new magnets. The fine Structure of the septum nose needed several trials in the construction until we found the final solution. The measured residual stray fields in the ring tube are even smaller than was expected from the model calculations.}}, author = {{Lindgren, Lars-Johan and Anderberg, B}}, issn = {{0167-5087}}, keywords = {{storage ring; septum; accelerator; magnet; injection}}, language = {{eng}}, number = {{2-3}}, pages = {{686--689}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{The new septum magnets}}, url = {{http://dx.doi.org/10.1016/j.nima.2005.04.006}}, doi = {{10.1016/j.nima.2005.04.006}}, volume = {{547}}, year = {{2005}}, }