Valvular imaging in the era of feature-tracking : A slice-following cardiac MR sequence to measure mitral flow

Seemann, Felicia LU ; Heiberg, Einar LU ; Carlsson, Marcus LU ; Gonzales, Ricardo A LU orcid ; Baldassarre, Lauren A ; Qiu, Maolin and Peters, Dana C (2020) In Journal of Magnetic Resonance Imaging 51(5). p.1412-1421
Abstract

BACKGROUND: In mitral valve dysfunction, noninvasive measurement of transmitral blood flow is an important clinical examination. Flow imaging of the mitral valve, however, is challenging, since it moves in and out of the image plane during the cardiac cycle.

PURPOSE: To more accurately measure mitral flow, a slice-following MRI phase contrast sequence is proposed. This study aimed to implement such a sequence, validate its slice-following functionality in a phantom and healthy subjects, and test its feasibility in patients with mitral valve dysfunction.

STUDY TYPE: Prospective.

PHANTOM AND SUBJECTS: The slice-following functionality was validated in a cone-shaped phantom by measuring the depicted slice radius. Sixteen... (More)

BACKGROUND: In mitral valve dysfunction, noninvasive measurement of transmitral blood flow is an important clinical examination. Flow imaging of the mitral valve, however, is challenging, since it moves in and out of the image plane during the cardiac cycle.

PURPOSE: To more accurately measure mitral flow, a slice-following MRI phase contrast sequence is proposed. This study aimed to implement such a sequence, validate its slice-following functionality in a phantom and healthy subjects, and test its feasibility in patients with mitral valve dysfunction.

STUDY TYPE: Prospective.

PHANTOM AND SUBJECTS: The slice-following functionality was validated in a cone-shaped phantom by measuring the depicted slice radius. Sixteen healthy subjects and 10 mitral valve dysfunction patients were enrolled at two sites.

FIELD STRENGTH/SEQUENCE: 1.5T and 3T gradient echo cine phase contrast.

ASSESSMENT: A single breath-hold retrospectively gated sequence using offline feature-tracking of the mitral valve was developed. Valve displacements were measured and imported to the scanner, allowing the slice position to change dynamically based on the cardiac phase. Mitral valve imaging was performed with slice-following and static imaging planes. Validation was performed by comparing mitral stroke volume with planimetric and aortic stroke volume.

STATISTICAL TESTS: Measurements were compared using linear regression, Pearson's R, parametric paired t-tests, Bland-Altman analysis, and intraclass correlation coefficient (ICC).

RESULTS: Phantom experiments confirmed accurate slice displacements. Slice-following was feasible in all subjects, yielding physiologically accurate mitral flow patterns. In healthy subjects, mitral and aortic stroke volumes agreed, with ICC = 0.72 and 0.90 for static and slice-following planes; with bias ±1 SDs 23.2 ± 13.2 mls and 8.4 ± 10.8 mls, respectively. Agreement with planimetry was stronger, with ICC = 0.84 and 0.96; bias ±1 SDs 13.7 ± 13.7 mls and -2.0 ± 8.8 mls for static and slice-following planes, respectively.

DATA CONCLUSION: Slice-following outperformed the conventional sequence and improved the accuracy of transmitral flow, which is important for assessment of diastolic function and mitral regurgitation.

LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Magnetic Resonance Imaging
volume
51
issue
5
pages
10 pages
publisher
John Wiley & Sons Inc.
external identifiers
  • pmid:31654470
  • scopus:85074568826
ISSN
1522-2586
DOI
10.1002/jmri.26971
language
English
LU publication?
yes
additional info
© 2019 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
id
24987a10-69c7-4560-a7ef-4bc60128e001
date added to LUP
2019-11-03 14:35:21
date last changed
2024-06-26 05:28:55
@article{24987a10-69c7-4560-a7ef-4bc60128e001,
  abstract     = {{<p>BACKGROUND: In mitral valve dysfunction, noninvasive measurement of transmitral blood flow is an important clinical examination. Flow imaging of the mitral valve, however, is challenging, since it moves in and out of the image plane during the cardiac cycle.</p><p>PURPOSE: To more accurately measure mitral flow, a slice-following MRI phase contrast sequence is proposed. This study aimed to implement such a sequence, validate its slice-following functionality in a phantom and healthy subjects, and test its feasibility in patients with mitral valve dysfunction.</p><p>STUDY TYPE: Prospective.</p><p>PHANTOM AND SUBJECTS: The slice-following functionality was validated in a cone-shaped phantom by measuring the depicted slice radius. Sixteen healthy subjects and 10 mitral valve dysfunction patients were enrolled at two sites.</p><p>FIELD STRENGTH/SEQUENCE: 1.5T and 3T gradient echo cine phase contrast.</p><p>ASSESSMENT: A single breath-hold retrospectively gated sequence using offline feature-tracking of the mitral valve was developed. Valve displacements were measured and imported to the scanner, allowing the slice position to change dynamically based on the cardiac phase. Mitral valve imaging was performed with slice-following and static imaging planes. Validation was performed by comparing mitral stroke volume with planimetric and aortic stroke volume.</p><p>STATISTICAL TESTS: Measurements were compared using linear regression, Pearson's R, parametric paired t-tests, Bland-Altman analysis, and intraclass correlation coefficient (ICC).</p><p>RESULTS: Phantom experiments confirmed accurate slice displacements. Slice-following was feasible in all subjects, yielding physiologically accurate mitral flow patterns. In healthy subjects, mitral and aortic stroke volumes agreed, with ICC = 0.72 and 0.90 for static and slice-following planes; with bias ±1 SDs 23.2 ± 13.2 mls and 8.4 ± 10.8 mls, respectively. Agreement with planimetry was stronger, with ICC = 0.84 and 0.96; bias ±1 SDs 13.7 ± 13.7 mls and -2.0 ± 8.8 mls for static and slice-following planes, respectively.</p><p>DATA CONCLUSION: Slice-following outperformed the conventional sequence and improved the accuracy of transmitral flow, which is important for assessment of diastolic function and mitral regurgitation.</p><p>LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019.</p>}},
  author       = {{Seemann, Felicia and Heiberg, Einar and Carlsson, Marcus and Gonzales, Ricardo A and Baldassarre, Lauren A and Qiu, Maolin and Peters, Dana C}},
  issn         = {{1522-2586}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{1412--1421}},
  publisher    = {{John Wiley & Sons Inc.}},
  series       = {{Journal of Magnetic Resonance Imaging}},
  title        = {{Valvular imaging in the era of feature-tracking : A slice-following cardiac MR sequence to measure mitral flow}},
  url          = {{http://dx.doi.org/10.1002/jmri.26971}},
  doi          = {{10.1002/jmri.26971}},
  volume       = {{51}},
  year         = {{2020}},
}