Microbial BOD sensors for wastewater analysis
(2002) In Water Research 36(15). p.3786-3802- Abstract
- The field of biosensors for measuring biochemical oxygen demand (BOD) is reviewed. Particularly, BOD sensors constructed on the biofilm configuration are discussed regarding performance characteristics like linearity, response time, precision, agreement between BOD values obtained from the biosensors and the conventional 5-days test, as well as toxic resistance to various compounds and operational stability. The techniques for improving the agreement between the sensor BOD and BOD5 are described. Information provided also includes BOD biosensors based on respirometers and other measuring principles, the commercial BOD instruments, as well as the current limitations of BOD biosensor development.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/325832
- author
- Liu, Jing LU and Mattiasson, Bo LU
- organization
- publishing date
- 2002
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- BOD, short-term, biochemical oxygen demand (BOD), BOD sensors, biosensors, biofilm, wastewater
- in
- Water Research
- volume
- 36
- issue
- 15
- pages
- 3786 - 3802
- publisher
- Elsevier
- external identifiers
-
- pmid:12369525
- wos:000178394500012
- scopus:0036741479
- ISSN
- 1879-2448
- DOI
- 10.1016/S0043-1354(02)00101-X
- language
- English
- LU publication?
- yes
- id
- 243176da-f6a6-4672-8081-a75c043d5b23 (old id 325832)
- date added to LUP
- 2016-04-01 15:58:21
- date last changed
- 2022-04-22 18:37:51
@article{243176da-f6a6-4672-8081-a75c043d5b23, abstract = {{The field of biosensors for measuring biochemical oxygen demand (BOD) is reviewed. Particularly, BOD sensors constructed on the biofilm configuration are discussed regarding performance characteristics like linearity, response time, precision, agreement between BOD values obtained from the biosensors and the conventional 5-days test, as well as toxic resistance to various compounds and operational stability. The techniques for improving the agreement between the sensor BOD and BOD5 are described. Information provided also includes BOD biosensors based on respirometers and other measuring principles, the commercial BOD instruments, as well as the current limitations of BOD biosensor development.}}, author = {{Liu, Jing and Mattiasson, Bo}}, issn = {{1879-2448}}, keywords = {{BOD; short-term; biochemical oxygen demand (BOD); BOD sensors; biosensors; biofilm; wastewater}}, language = {{eng}}, number = {{15}}, pages = {{3786--3802}}, publisher = {{Elsevier}}, series = {{Water Research}}, title = {{Microbial BOD sensors for wastewater analysis}}, url = {{http://dx.doi.org/10.1016/S0043-1354(02)00101-X}}, doi = {{10.1016/S0043-1354(02)00101-X}}, volume = {{36}}, year = {{2002}}, }