MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT applied for Dosimetry of Radiopharmaceutical Therapy.

Ljungberg, Michael LU ; Celler, Anna ; Konijnenberg, Mark W ; Eckerman, Keith F ; Dewaraja, Yuni K and Sjögreen Gleisner, Katarina LU (2016) In Journal of Nuclear Medicine 57(1). p.151-162
Abstract
Accuracy of absorbed dose calculations in personalized internal radionuclide therapy is directly related to the accuracy of the activity (or activity concentration) estimates obtained at each of the imaging time points. MIRD Pamphlet No. 23 presented a general overview of methods that are required for quantitative SPECT imaging. The present document is next in a series of isotope-specific guidelines and recommendations that follow the general information that was provided in MIRD 23. This paper focuses on 177-Lu (Lutetium) and its main application in radiopharmaceutical therapy.
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Nuclear Medicine
volume
57
issue
1
pages
151 - 162
publisher
Society of Nuclear Medicine
external identifiers
  • pmid:26471692
  • wos:000367862700026
  • scopus:84958616819
  • pmid:26471692
ISSN
0161-5505
DOI
10.2967/jnumed.115.159012
language
English
LU publication?
yes
id
b7bfa622-4d04-454b-8e66-908a6a4b33c4 (old id 8152143)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/26471692?dopt=Abstract
date added to LUP
2016-04-01 11:04:41
date last changed
2022-04-28 03:58:53
@article{b7bfa622-4d04-454b-8e66-908a6a4b33c4,
  abstract     = {{Accuracy of absorbed dose calculations in personalized internal radionuclide therapy is directly related to the accuracy of the activity (or activity concentration) estimates obtained at each of the imaging time points. MIRD Pamphlet No. 23 presented a general overview of methods that are required for quantitative SPECT imaging. The present document is next in a series of isotope-specific guidelines and recommendations that follow the general information that was provided in MIRD 23. This paper focuses on 177-Lu (Lutetium) and its main application in radiopharmaceutical therapy.}},
  author       = {{Ljungberg, Michael and Celler, Anna and Konijnenberg, Mark W and Eckerman, Keith F and Dewaraja, Yuni K and Sjögreen Gleisner, Katarina}},
  issn         = {{0161-5505}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{151--162}},
  publisher    = {{Society of Nuclear Medicine}},
  series       = {{Journal of Nuclear Medicine}},
  title        = {{MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT applied for Dosimetry of Radiopharmaceutical Therapy.}},
  url          = {{http://dx.doi.org/10.2967/jnumed.115.159012}},
  doi          = {{10.2967/jnumed.115.159012}},
  volume       = {{57}},
  year         = {{2016}},
}