Swiss pendulous hammer for decoupling measurement of service equipment in wooden multi-storey building
(2012) 9th European Conference on Noise Control, EURONOISE 2012 In Euronoise p.224-229- Abstract
The latest Swiss standard SIA181 (6-2006 edition [1]) introduces a new methodology regarding the tests to be performed in new constructions for assessing noise induced by the manipulation of service equipment in bathrooms and kitchens. However, this method has been developed especially for massive constructions. In this study, we are investigating the relevance of such method for timber frame building, with typical structures including boxes, frames, massive floors, retrofitting solutions. Decoupling performances are particularly important in lightweight constructions, and the pendulous hammer method is actually aiming at evaluating the decoupling of service equipments. The goals for this work are to determine the advantages and the... (More)
The latest Swiss standard SIA181 (6-2006 edition [1]) introduces a new methodology regarding the tests to be performed in new constructions for assessing noise induced by the manipulation of service equipment in bathrooms and kitchens. However, this method has been developed especially for massive constructions. In this study, we are investigating the relevance of such method for timber frame building, with typical structures including boxes, frames, massive floors, retrofitting solutions. Decoupling performances are particularly important in lightweight constructions, and the pendulous hammer method is actually aiming at evaluating the decoupling of service equipments. The goals for this work are to determine the advantages and the limitations of this method for theses specific cases. For example, airborne contribution can become critical and deserves a specific control. This project should also identify the main propagation paths for equipment noise. A series of in-situ measurements has been performed for various building constructions and service equipments. Some additional laboratories investigations have been conducted to optimize the decoupling of service equipments to fulfill the Swiss SIA standard requirements.
(Less)
- author
- Desarnaulds, Victor ; Lissek, Hervé ; Bard, Delphine LU and Beffa, Robert
- organization
- publishing date
- 2012-09-13
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- EURONOISE 2012 - 9th European Conference on Noise Control
- series title
- Euronoise
- pages
- 6 pages
- publisher
- European Acoustics Association
- conference name
- 9th European Conference on Noise Control, EURONOISE 2012
- conference location
- Prague, Czech Republic
- conference dates
- 2012-06-10 - 2012-06-13
- external identifiers
-
- scopus:84865994697
- ISSN
- 2226-5147
- ISBN
- 9788001050132
- language
- English
- LU publication?
- yes
- id
- bfaf007a-5314-4740-8b1e-314559723cb2
- date added to LUP
- 2019-05-21 15:30:04
- date last changed
- 2022-01-31 20:27:34
@inproceedings{bfaf007a-5314-4740-8b1e-314559723cb2, abstract = {{<p>The latest Swiss standard SIA181 (6-2006 edition [1]) introduces a new methodology regarding the tests to be performed in new constructions for assessing noise induced by the manipulation of service equipment in bathrooms and kitchens. However, this method has been developed especially for massive constructions. In this study, we are investigating the relevance of such method for timber frame building, with typical structures including boxes, frames, massive floors, retrofitting solutions. Decoupling performances are particularly important in lightweight constructions, and the pendulous hammer method is actually aiming at evaluating the decoupling of service equipments. The goals for this work are to determine the advantages and the limitations of this method for theses specific cases. For example, airborne contribution can become critical and deserves a specific control. This project should also identify the main propagation paths for equipment noise. A series of in-situ measurements has been performed for various building constructions and service equipments. Some additional laboratories investigations have been conducted to optimize the decoupling of service equipments to fulfill the Swiss SIA standard requirements.</p>}}, author = {{Desarnaulds, Victor and Lissek, Hervé and Bard, Delphine and Beffa, Robert}}, booktitle = {{EURONOISE 2012 - 9th European Conference on Noise Control}}, isbn = {{9788001050132}}, issn = {{2226-5147}}, language = {{eng}}, month = {{09}}, pages = {{224--229}}, publisher = {{European Acoustics Association}}, series = {{Euronoise}}, title = {{Swiss pendulous hammer for decoupling measurement of service equipment in wooden multi-storey building}}, year = {{2012}}, }