Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Quantitative picosecond laser-induced fluorescence measurements of nitric oxide in flames

Brackmann, Christian LU ; Bood, Joakim LU ; Nauclér, Jenny D. LU ; Konnov, Alexander A. LU and Aldén, Marcus LU (2017) In Proceedings of the Combustion Institute 36(3). p.4533-4540
Abstract

Quantitative concentrations measurements using time-resolved laser-induced fluorescence have been demonstrated for nitric oxide (NO) in flame. Fluorescence lifetimes measured using a picosecond Nd:YAG laser and optical parametric amplifier system have been used to directly compensate the measured signal for collisional quenching and evaluate NO concentration. The full evaluation also includes the spectral overlap between the ∼15cm-1 broad laser pulse and multiple NO absorption lines as well as the populations of the probed energy levels. Effective fluorescence lifetimes of 1.2 and 1.5ns were measured in prepared NO/N2/O2 mixtures at ambient pressure and temperature and in a premixed NH3-seeded... (More)

Quantitative concentrations measurements using time-resolved laser-induced fluorescence have been demonstrated for nitric oxide (NO) in flame. Fluorescence lifetimes measured using a picosecond Nd:YAG laser and optical parametric amplifier system have been used to directly compensate the measured signal for collisional quenching and evaluate NO concentration. The full evaluation also includes the spectral overlap between the ∼15cm-1 broad laser pulse and multiple NO absorption lines as well as the populations of the probed energy levels. Effective fluorescence lifetimes of 1.2 and 1.5ns were measured in prepared NO/N2/O2 mixtures at ambient pressure and temperature and in a premixed NH3-seeded CH4/N2/O2 flame, respectively. Concentrations evaluated from measurements in NO/N2/O2 mixtures with NO concentrations of 100-600ppm were in agreement with set values within 3% at higher concentrations. An accuracy of 13% was estimated by analysis of experimental uncertainties. An NO profile measured in the flame showed concentrations of ∼1000ppm in the post-flame region and is in good agreement with NO concentrations predicted by a chemical mechanism for NH3 combustion. An accuracy of 16% was estimated for the flame measurements. The direct concentration evaluation from time-resolved fluorescence allows for quantitative measurements in flames where the composition of major species and their collisional quenching on the probed species is unknown. In particular, this is valid for non-stationary turbulent combustion and implementation of the presented approach for measurements under such conditions is discussed.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Concentration measurements, Laser-induced fluorescence, Nitric oxide, NO
in
Proceedings of the Combustion Institute
volume
36
issue
3
pages
4533 - 4540
publisher
Elsevier
external identifiers
  • scopus:84978805848
  • wos:000393412600135
ISSN
1540-7489
DOI
10.1016/j.proci.2016.07.012
language
English
LU publication?
yes
id
d9364fe1-0360-4c70-99fc-adfcda322d80
date added to LUP
2016-12-22 13:25:51
date last changed
2024-04-19 15:51:42
@article{d9364fe1-0360-4c70-99fc-adfcda322d80,
  abstract     = {{<p>Quantitative concentrations measurements using time-resolved laser-induced fluorescence have been demonstrated for nitric oxide (NO) in flame. Fluorescence lifetimes measured using a picosecond Nd:YAG laser and optical parametric amplifier system have been used to directly compensate the measured signal for collisional quenching and evaluate NO concentration. The full evaluation also includes the spectral overlap between the ∼15cm<sup>-1</sup> broad laser pulse and multiple NO absorption lines as well as the populations of the probed energy levels. Effective fluorescence lifetimes of 1.2 and 1.5ns were measured in prepared NO/N<sub>2</sub>/O<sub>2</sub> mixtures at ambient pressure and temperature and in a premixed NH<sub>3</sub>-seeded CH<sub>4</sub>/N<sub>2</sub>/O<sub>2</sub> flame, respectively. Concentrations evaluated from measurements in NO/N<sub>2</sub>/O<sub>2</sub> mixtures with NO concentrations of 100-600ppm were in agreement with set values within 3% at higher concentrations. An accuracy of 13% was estimated by analysis of experimental uncertainties. An NO profile measured in the flame showed concentrations of ∼1000ppm in the post-flame region and is in good agreement with NO concentrations predicted by a chemical mechanism for NH<sub>3</sub> combustion. An accuracy of 16% was estimated for the flame measurements. The direct concentration evaluation from time-resolved fluorescence allows for quantitative measurements in flames where the composition of major species and their collisional quenching on the probed species is unknown. In particular, this is valid for non-stationary turbulent combustion and implementation of the presented approach for measurements under such conditions is discussed.</p>}},
  author       = {{Brackmann, Christian and Bood, Joakim and Nauclér, Jenny D. and Konnov, Alexander A. and Aldén, Marcus}},
  issn         = {{1540-7489}},
  keywords     = {{Concentration measurements; Laser-induced fluorescence; Nitric oxide; NO}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{4533--4540}},
  publisher    = {{Elsevier}},
  series       = {{Proceedings of the Combustion Institute}},
  title        = {{Quantitative picosecond laser-induced fluorescence measurements of nitric oxide in flames}},
  url          = {{https://lup.lub.lu.se/search/files/119482921/Brackmann_PROCI_36_2017.pdf}},
  doi          = {{10.1016/j.proci.2016.07.012}},
  volume       = {{36}},
  year         = {{2017}},
}