Diagnostics at the MAX IV 3 GeV storage ring during commissioning
(2016) 5th International Beam Instrumentation Conference, IBIC 2016 p.1-5- Abstract
The MAX IV 3 GeV storage ring based on a multibend achromat lattice allows for horizontal emittances from 330 pm rad down to 180 pm rad, depending on the number of insertion devices. The diagnostics used during commissioning will be described, with emphasis on the emittance diagnostics. This will involve two diagnostic beam lines to image the electron beam with infrared and ultraviolet synchrotron radiation from bending magnets, in order to determine also beam energy spread. The scheme for horizontal emittance measurements looks promising also for an order of magnitude lower emittance. Bunch lengthening with harmonic cavities is essential for the low emittance machine performance. We have used a radiation-based sampling technique to... (More)
The MAX IV 3 GeV storage ring based on a multibend achromat lattice allows for horizontal emittances from 330 pm rad down to 180 pm rad, depending on the number of insertion devices. The diagnostics used during commissioning will be described, with emphasis on the emittance diagnostics. This will involve two diagnostic beam lines to image the electron beam with infrared and ultraviolet synchrotron radiation from bending magnets, in order to determine also beam energy spread. The scheme for horizontal emittance measurements looks promising also for an order of magnitude lower emittance. Bunch lengthening with harmonic cavities is essential for the low emittance machine performance. We have used a radiation-based sampling technique to verify individual bunch distributions.
(Less)
- author
- Andersson LU ; Breunlin, J. LU ; Jensen, B. N. LU ; Lindvall, R. LU ; Mansten, E. LU ; Olsson, D. LU ; Sundberg, J. LU ; Tavares, P. F. LU and Thorin, S. LU
- organization
- publishing date
- 2016
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- Proceedings of the 5th International Beam Instrumentation Conference, IBIC 2016
- pages
- 1 - 5
- publisher
- JACoW Publishing
- conference name
- 5th International Beam Instrumentation Conference, IBIC 2016
- conference location
- Barcelona, Spain
- conference dates
- 2016-09-11 - 2016-09-15
- external identifiers
-
- scopus:85072015785
- ISBN
- 9783954501779
- language
- English
- LU publication?
- yes
- id
- ee703384-cb3d-499a-8deb-9a4ce2250464
- date added to LUP
- 2019-11-12 11:18:53
- date last changed
- 2022-02-01 01:55:11
@inproceedings{ee703384-cb3d-499a-8deb-9a4ce2250464, abstract = {{<p>The MAX IV 3 GeV storage ring based on a multibend achromat lattice allows for horizontal emittances from 330 pm rad down to 180 pm rad, depending on the number of insertion devices. The diagnostics used during commissioning will be described, with emphasis on the emittance diagnostics. This will involve two diagnostic beam lines to image the electron beam with infrared and ultraviolet synchrotron radiation from bending magnets, in order to determine also beam energy spread. The scheme for horizontal emittance measurements looks promising also for an order of magnitude lower emittance. Bunch lengthening with harmonic cavities is essential for the low emittance machine performance. We have used a radiation-based sampling technique to verify individual bunch distributions.</p>}}, author = {{Andersson and Breunlin, J. and Jensen, B. N. and Lindvall, R. and Mansten, E. and Olsson, D. and Sundberg, J. and Tavares, P. F. and Thorin, S.}}, booktitle = {{Proceedings of the 5th International Beam Instrumentation Conference, IBIC 2016}}, isbn = {{9783954501779}}, language = {{eng}}, pages = {{1--5}}, publisher = {{JACoW Publishing}}, title = {{Diagnostics at the MAX IV 3 GeV storage ring during commissioning}}, year = {{2016}}, }