Strahlendosis bei renaler Vergrosserungsangiographie im Vergleich mit konventioneller Angiographie
(1978) In Radiologe 18(5). p.175-178- Abstract
- Measurements of skin dose, integrated skin dose area, and integral dose in combined conventional and magnification renal angiography using lanthanoxibromide screens MR 600 and carbon fibre plate in filmchangertop have been made. The mean skin dose in magnification technique was 0.56 rad./film with focus-skin distance of 35 cm, FFD 1 m, 85-90 kV and sagittal diameter of abdomen of 20 cm. The combination of angiographic technique with and without magnification and the use of a high-sensitivity receiving unit makes it possible to keep the total skin dose per investigation (8.5 rad.) within the limits accepted in conventional abdominal angiography.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1102655
- author
- Maly, Pavel LU and Knöös, Tommy LU
- organization
- alternative title
- Radiation dose in renal magnification angiography compared with conventional angiography
- publishing date
- 1978
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Radiologe
- volume
- 18
- issue
- 5
- pages
- 175 - 178
- publisher
- Springer
- external identifiers
-
- pmid:652984
- scopus:0017973614
- ISSN
- 0033-832X
- language
- German
- LU publication?
- yes
- id
- 6cac3ae0-8ab4-4474-801c-ef77c949c031 (old id 1102655)
- date added to LUP
- 2016-04-01 16:32:36
- date last changed
- 2021-01-03 11:37:06
@article{6cac3ae0-8ab4-4474-801c-ef77c949c031, abstract = {{Measurements of skin dose, integrated skin dose area, and integral dose in combined conventional and magnification renal angiography using lanthanoxibromide screens MR 600 and carbon fibre plate in filmchangertop have been made. The mean skin dose in magnification technique was 0.56 rad./film with focus-skin distance of 35 cm, FFD 1 m, 85-90 kV and sagittal diameter of abdomen of 20 cm. The combination of angiographic technique with and without magnification and the use of a high-sensitivity receiving unit makes it possible to keep the total skin dose per investigation (8.5 rad.) within the limits accepted in conventional abdominal angiography.}}, author = {{Maly, Pavel and Knöös, Tommy}}, issn = {{0033-832X}}, language = {{ger}}, number = {{5}}, pages = {{175--178}}, publisher = {{Springer}}, series = {{Radiologe}}, title = {{Strahlendosis bei renaler Vergrosserungsangiographie im Vergleich mit konventioneller Angiographie}}, volume = {{18}}, year = {{1978}}, }