Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Strahlendosis bei renaler Vergrosserungsangiographie im Vergleich mit konventioneller Angiographie

Maly, Pavel LU and Knöös, Tommy LU orcid (1978) In Radiologe 18(5). p.175-178
Abstract
Measurements of skin dose, integrated skin dose area, and integral dose in combined conventional and magnification renal angiography using lanthanoxibromide screens MR 600 and carbon fibre plate in filmchangertop have been made. The mean skin dose in magnification technique was 0.56 rad./film with focus-skin distance of 35 cm, FFD 1 m, 85-90 kV and sagittal diameter of abdomen of 20 cm. The combination of angiographic technique with and without magnification and the use of a high-sensitivity receiving unit makes it possible to keep the total skin dose per investigation (8.5 rad.) within the limits accepted in conventional abdominal angiography.
Please use this url to cite or link to this publication:
author
and
organization
alternative title
Radiation dose in renal magnification angiography compared with conventional angiography
publishing date
type
Contribution to journal
publication status
published
subject
in
Radiologe
volume
18
issue
5
pages
175 - 178
publisher
Springer
external identifiers
  • pmid:652984
  • scopus:0017973614
ISSN
0033-832X
language
German
LU publication?
yes
id
6cac3ae0-8ab4-4474-801c-ef77c949c031 (old id 1102655)
date added to LUP
2016-04-01 16:32:36
date last changed
2021-01-03 11:37:06
@article{6cac3ae0-8ab4-4474-801c-ef77c949c031,
  abstract     = {{Measurements of skin dose, integrated skin dose area, and integral dose in combined conventional and magnification renal angiography using lanthanoxibromide screens MR 600 and carbon fibre plate in filmchangertop have been made. The mean skin dose in magnification technique was 0.56 rad./film with focus-skin distance of 35 cm, FFD 1 m, 85-90 kV and sagittal diameter of abdomen of 20 cm. The combination of angiographic technique with and without magnification and the use of a high-sensitivity receiving unit makes it possible to keep the total skin dose per investigation (8.5 rad.) within the limits accepted in conventional abdominal angiography.}},
  author       = {{Maly, Pavel and Knöös, Tommy}},
  issn         = {{0033-832X}},
  language     = {{ger}},
  number       = {{5}},
  pages        = {{175--178}},
  publisher    = {{Springer}},
  series       = {{Radiologe}},
  title        = {{Strahlendosis bei renaler Vergrosserungsangiographie im Vergleich mit konventioneller Angiographie}},
  volume       = {{18}},
  year         = {{1978}},
}