Amine-based aqueous polymers for the simultaneous titration and extraction of lactic acid in aqueous two-phase systems
(1998) In Journal of Chromatography. B 711(1-2). p.265-275- Abstract
- The partitioning of 10% (w/w) lactic acid in ethylene oxide propylene oxide (EOPO) random copolymers and dextran T500 aqueous two-phase systems was studied. An analysis of variance design was applied to investigate the effect of pH, polymer concentration, and addition of polyethyleneimine to the aqueous two-phase systems. The lowest lactate partition coefficient of 0.09 was obtained at pH 6 in the systems containing 7.2% (w/w) polyethyleneimine. The use of polyethyleneimine as titrating base during the fermentative production of lactic acid was evaluated in batch fermentations with 100 g/l glucose. Yield and productivity of polyethyleneimine titrated fermentations compared with those obtained in fermentations titrated with NaOH and KOH.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/125598
- author
- Planas, Jordi ; Varelas, Vassilios ; Tjerneld, Folke LU and Hahn-Hägerdal, Bärbel LU
- organization
- publishing date
- 1998
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Lactic acid
- in
- Journal of Chromatography. B
- volume
- 711
- issue
- 1-2
- pages
- 265 - 275
- publisher
- Elsevier
- external identifiers
-
- scopus:0032569068
- ISSN
- 1387-2273
- DOI
- 10.1016/S0378-4347(97)00663-4
- language
- English
- LU publication?
- yes
- id
- f12d8d08-af64-4388-9485-602026c90c8a (old id 125598)
- date added to LUP
- 2016-04-04 10:21:26
- date last changed
- 2022-01-29 20:09:56
@article{f12d8d08-af64-4388-9485-602026c90c8a, abstract = {{The partitioning of 10% (w/w) lactic acid in ethylene oxide propylene oxide (EOPO) random copolymers and dextran T500 aqueous two-phase systems was studied. An analysis of variance design was applied to investigate the effect of pH, polymer concentration, and addition of polyethyleneimine to the aqueous two-phase systems. The lowest lactate partition coefficient of 0.09 was obtained at pH 6 in the systems containing 7.2% (w/w) polyethyleneimine. The use of polyethyleneimine as titrating base during the fermentative production of lactic acid was evaluated in batch fermentations with 100 g/l glucose. Yield and productivity of polyethyleneimine titrated fermentations compared with those obtained in fermentations titrated with NaOH and KOH.}}, author = {{Planas, Jordi and Varelas, Vassilios and Tjerneld, Folke and Hahn-Hägerdal, Bärbel}}, issn = {{1387-2273}}, keywords = {{Lactic acid}}, language = {{eng}}, number = {{1-2}}, pages = {{265--275}}, publisher = {{Elsevier}}, series = {{Journal of Chromatography. B}}, title = {{Amine-based aqueous polymers for the simultaneous titration and extraction of lactic acid in aqueous two-phase systems}}, url = {{http://dx.doi.org/10.1016/S0378-4347(97)00663-4}}, doi = {{10.1016/S0378-4347(97)00663-4}}, volume = {{711}}, year = {{1998}}, }