First results from the Lund NMP particle detector system
(2009) 11th International Conference on Nuclear Microprobe Technology and Applications/3rd International Workshop on Proton Beam Writing 267(12-13). p.2065-2068- Abstract
- The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions. (C) 2009 Elsevier B.V. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1462399
- author
- Golubev, Pavel LU ; Kristiansson, Per LU ; Arteaga, Natalia LU ; Elfman, Mikael LU ; Malmqvist, Klas LU ; Fors, Erik LU ; Nilsson, Christer LU ; Pallon, Jan LU and Wegdén, Marie LU
- organization
- publishing date
- 2009
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- RBS, Nuclear microprobe, NRA, Silicon strip detectors, Detector array
- host publication
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- volume
- 267
- issue
- 12-13
- pages
- 2065 - 2068
- publisher
- Elsevier
- conference name
- 11th International Conference on Nuclear Microprobe Technology and Applications/3rd International Workshop on Proton Beam Writing
- conference location
- Debrecen, Hungary
- conference dates
- 2008-07-20 - 2008-07-25
- external identifiers
-
- wos:000267910500018
- scopus:66349103045
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2009.03.030
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007), Department of Physics (011013000)
- id
- 550d215d-d838-4110-a5c6-7ccc84259072 (old id 1462399)
- date added to LUP
- 2016-04-01 14:38:23
- date last changed
- 2022-03-22 01:07:36
@inproceedings{550d215d-d838-4110-a5c6-7ccc84259072, abstract = {{The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions. (C) 2009 Elsevier B.V. All rights reserved.}}, author = {{Golubev, Pavel and Kristiansson, Per and Arteaga, Natalia and Elfman, Mikael and Malmqvist, Klas and Fors, Erik and Nilsson, Christer and Pallon, Jan and Wegdén, Marie}}, booktitle = {{Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms}}, issn = {{0168-583X}}, keywords = {{RBS; Nuclear microprobe; NRA; Silicon strip detectors; Detector array}}, language = {{eng}}, number = {{12-13}}, pages = {{2065--2068}}, publisher = {{Elsevier}}, title = {{First results from the Lund NMP particle detector system}}, url = {{http://dx.doi.org/10.1016/j.nimb.2009.03.030}}, doi = {{10.1016/j.nimb.2009.03.030}}, volume = {{267}}, year = {{2009}}, }