Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

The influence of feed flow channel diameter on frictional pressure drop, membrane performance and process cost in full-scale tubular ceramic membranes

Krawczyk, Holger LU and Jönsson, Ann-Sofi LU (2014) In Chemical Engineering Research & Design 92(1). p.174-180
Abstract
Tubular ceramic membranes with many, small-diameter feed flow channels have the advantage of being less costly per unit membrane area. For this reason, membranes with many small channels are often favored over those with fewer larger channels. We have theoretically studied how the diameter of the feed flow channels influences the frictional pressure drop, the membrane performance (flux and retention) and the process cost by performing basic pressure drop calculations and using experimental data from bench-scale experiments. The investigation was carried out on a model microfiltration process consisting of the separation of yeast cells from polyethylene glycol (PEG) macromolecules. For a membrane with 2.5 mm channels the average flux and... (More)
Tubular ceramic membranes with many, small-diameter feed flow channels have the advantage of being less costly per unit membrane area. For this reason, membranes with many small channels are often favored over those with fewer larger channels. We have theoretically studied how the diameter of the feed flow channels influences the frictional pressure drop, the membrane performance (flux and retention) and the process cost by performing basic pressure drop calculations and using experimental data from bench-scale experiments. The investigation was carried out on a model microfiltration process consisting of the separation of yeast cells from polyethylene glycol (PEG) macromolecules. For a membrane with 2.5 mm channels the average flux and PEG retention were 112 L/m(2)h and 22%, respectively, differing significantly from a membrane with 6.0 mm channel diameter (131 L/m(2)h, 17%), under the same hydrodynamic conditions. The choice of channel diameter also has a considerable impact on the process cost. While the costs were similar for membranes with 6.0 and 3.8 mm diameter channels, they were about 55% higher using a membrane with 2.5 mm channels. This high cost was mainly attributed to the high frictional pressure drop along the membrane, which increases the energy required for pumping. (C) 2013 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Microfiltration, Tubular membrane, Channel diameter, Frictional pressure, drop, Cake formation, Cost estimate
in
Chemical Engineering Research & Design
volume
92
issue
1
pages
174 - 180
publisher
Institution of Chemical Engineers
external identifiers
  • wos:000331501600016
  • scopus:84892779710
ISSN
0263-8762
DOI
10.1016/j.cherd.2013.06.019
language
English
LU publication?
yes
id
26906374-c4e1-468e-8bd7-fa1ec9cafb6c (old id 4376221)
date added to LUP
2016-04-01 13:44:42
date last changed
2023-10-01 06:07:19
@article{26906374-c4e1-468e-8bd7-fa1ec9cafb6c,
  abstract     = {{Tubular ceramic membranes with many, small-diameter feed flow channels have the advantage of being less costly per unit membrane area. For this reason, membranes with many small channels are often favored over those with fewer larger channels. We have theoretically studied how the diameter of the feed flow channels influences the frictional pressure drop, the membrane performance (flux and retention) and the process cost by performing basic pressure drop calculations and using experimental data from bench-scale experiments. The investigation was carried out on a model microfiltration process consisting of the separation of yeast cells from polyethylene glycol (PEG) macromolecules. For a membrane with 2.5 mm channels the average flux and PEG retention were 112 L/m(2)h and 22%, respectively, differing significantly from a membrane with 6.0 mm channel diameter (131 L/m(2)h, 17%), under the same hydrodynamic conditions. The choice of channel diameter also has a considerable impact on the process cost. While the costs were similar for membranes with 6.0 and 3.8 mm diameter channels, they were about 55% higher using a membrane with 2.5 mm channels. This high cost was mainly attributed to the high frictional pressure drop along the membrane, which increases the energy required for pumping. (C) 2013 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.}},
  author       = {{Krawczyk, Holger and Jönsson, Ann-Sofi}},
  issn         = {{0263-8762}},
  keywords     = {{Microfiltration; Tubular membrane; Channel diameter; Frictional pressure; drop; Cake formation; Cost estimate}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{174--180}},
  publisher    = {{Institution of Chemical Engineers}},
  series       = {{Chemical Engineering Research & Design}},
  title        = {{The influence of feed flow channel diameter on frictional pressure drop, membrane performance and process cost in full-scale tubular ceramic membranes}},
  url          = {{http://dx.doi.org/10.1016/j.cherd.2013.06.019}},
  doi          = {{10.1016/j.cherd.2013.06.019}},
  volume       = {{92}},
  year         = {{2014}},
}