Evaluation of a pre-cell hit detector for the future single ion hit facility in Lund
(2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 249(1-2). p.924-927- Abstract
- Currently, a single ion hit facility, for irradiation of single cells with single, light MeV ions is under development at the Lund Nuclear Microprobe. In this paper, a novel approach to the ion detection issue is presented. A silicon detector, a type utilized at other facilities for post-cell ion detection, has been investigated as a possible option for pre-cell hit detection. If proven successful, this detector could possibly also be used simultaneously as vacuum window. The first experiments carried out on the 9 mu m thick silicon detector, with an area of 4 mm(2), have been aimed at investigations of signal-to-noise ratio and efficiency. The results thus far reveal a low noise level and a noise distribution, which is well separated from... (More)
- Currently, a single ion hit facility, for irradiation of single cells with single, light MeV ions is under development at the Lund Nuclear Microprobe. In this paper, a novel approach to the ion detection issue is presented. A silicon detector, a type utilized at other facilities for post-cell ion detection, has been investigated as a possible option for pre-cell hit detection. If proven successful, this detector could possibly also be used simultaneously as vacuum window. The first experiments carried out on the 9 mu m thick silicon detector, with an area of 4 mm(2), have been aimed at investigations of signal-to-noise ratio and efficiency. The results thus far reveal a low noise level and a noise distribution, which is well separated from the signal peak. However, the efficiency remains a problem, since at present it is far from the required 100%. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/398302
- author
- Nilsson, Charlotta LU ; Pallon, Jan LU ; Thungstrom, Goran ; Arteaga, Natalia LU ; Auzelyte, Vaida LU ; Elfman, Mikael LU ; Kristiansson, Per LU ; Nilsson, Christer LU and Wegdén, Marie LU
- organization
- publishing date
- 2006
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- SIHF, Delta E detector, thin silicon detector, single ions, single cells
- in
- Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
- volume
- 249
- issue
- 1-2
- pages
- 924 - 927
- publisher
- Elsevier
- external identifiers
-
- wos:000239545000224
- scopus:33745856978
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2006.03.165
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
- id
- 4104e3f6-69ba-4815-8c51-67fd1458bb20 (old id 398302)
- date added to LUP
- 2016-04-01 16:34:04
- date last changed
- 2022-01-28 20:34:06
@article{4104e3f6-69ba-4815-8c51-67fd1458bb20, abstract = {{Currently, a single ion hit facility, for irradiation of single cells with single, light MeV ions is under development at the Lund Nuclear Microprobe. In this paper, a novel approach to the ion detection issue is presented. A silicon detector, a type utilized at other facilities for post-cell ion detection, has been investigated as a possible option for pre-cell hit detection. If proven successful, this detector could possibly also be used simultaneously as vacuum window. The first experiments carried out on the 9 mu m thick silicon detector, with an area of 4 mm(2), have been aimed at investigations of signal-to-noise ratio and efficiency. The results thus far reveal a low noise level and a noise distribution, which is well separated from the signal peak. However, the efficiency remains a problem, since at present it is far from the required 100%.}}, author = {{Nilsson, Charlotta and Pallon, Jan and Thungstrom, Goran and Arteaga, Natalia and Auzelyte, Vaida and Elfman, Mikael and Kristiansson, Per and Nilsson, Christer and Wegdén, Marie}}, issn = {{0168-583X}}, keywords = {{SIHF; Delta E detector; thin silicon detector; single ions; single cells}}, language = {{eng}}, number = {{1-2}}, pages = {{924--927}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}}, title = {{Evaluation of a pre-cell hit detector for the future single ion hit facility in Lund}}, url = {{http://dx.doi.org/10.1016/j.nimb.2006.03.165}}, doi = {{10.1016/j.nimb.2006.03.165}}, volume = {{249}}, year = {{2006}}, }