On-off Control of an Active Load for Power System Damping - Theory and Field Test
(1999) IEEE Power Engineering Society 1999 Winter Meeting 14(2). p.608-613- Abstract
- Controlled resistive loads can contribute to damping of electro-mechanical oscillations. This paper presents an on-off damping controller for a single machine system. It was used at a field test in Southern Sweden to damp oscillations of a 0.9 MW hydro power generator. The controller used estimated machine frequency as input and controlled a 20 kW resistive load via thyristor switches. The field measurements are compared to time simulations and a systematic procedure for tuning the controller is given. The results indicate that on-off control of active loads is effective in terms of added damping and that it is simple to tune and implement
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4357686
- author
- Samuelsson, Olof LU and Akke, Magnus LU
- organization
- publishing date
- 1999
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- control system analysis control system synthesis damping hydroelectric generators hydroelectric power on-off control oscillations power system control
- host publication
- IEEE Transactions on Power Systems
- volume
- 14
- issue
- 2
- pages
- 608 - 613
- conference name
- IEEE Power Engineering Society 1999 Winter Meeting
- conference location
- Piscataway, New York, United States
- conference dates
- 1999-01-31
- external identifiers
-
- scopus:0032638896
- ISSN
- 0885-8950
- DOI
- 10.1109/59.761887
- language
- English
- LU publication?
- yes
- id
- 62fcd348-fe74-44b3-9053-29874511f5ba (old id 4357686)
- date added to LUP
- 2016-04-04 09:26:06
- date last changed
- 2022-01-29 17:49:21
@inproceedings{62fcd348-fe74-44b3-9053-29874511f5ba, abstract = {{Controlled resistive loads can contribute to damping of electro-mechanical oscillations. This paper presents an on-off damping controller for a single machine system. It was used at a field test in Southern Sweden to damp oscillations of a 0.9 MW hydro power generator. The controller used estimated machine frequency as input and controlled a 20 kW resistive load via thyristor switches. The field measurements are compared to time simulations and a systematic procedure for tuning the controller is given. The results indicate that on-off control of active loads is effective in terms of added damping and that it is simple to tune and implement}}, author = {{Samuelsson, Olof and Akke, Magnus}}, booktitle = {{IEEE Transactions on Power Systems}}, issn = {{0885-8950}}, keywords = {{control system analysis control system synthesis damping hydroelectric generators hydroelectric power on-off control oscillations power system control}}, language = {{eng}}, number = {{2}}, pages = {{608--613}}, title = {{On-off Control of an Active Load for Power System Damping - Theory and Field Test}}, url = {{http://dx.doi.org/10.1109/59.761887}}, doi = {{10.1109/59.761887}}, volume = {{14}}, year = {{1999}}, }