This paper presents a new analytical solution for the influence of regional groundwater flow on the performance of borehole heat exchangers. The solution concerns a vertical borehole. The transient thermal response for the fundamental case of a step-change in heat injection rate is given. The solution is remarkably simple and the formulas quite handy considering the complexity of the convective-diffusive heat flow process. The influence on the required borehole length for a ground-coupled heat pump is discussed.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
analytical solution, groundwater flow, ground-coupled heat pump, Borehole heat exchanger
host publication
Proceedings : TERRASTOCK 2000, 8th International Conference on Thermal Energy Storage
editor
Benner, Martin
publisher
[Publisher information missing]
conference name
8th International Conference on Thermal Energy Storage
conference location
University of Stuttgart, Germany
conference dates
2000-08-28 - 2000-09-01
ISBN
3-9805274-1-7
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Mathematical Physics (Faculty of Technology) (011040002), Building Physics (011033001)
id
e78f00aa-0d99-4611-850e-c9037ef13d10 (old id 8146474)
date added to LUP
2016-04-04 12:19:33
date last changed
2020-05-29 17:01:39
@inproceedings{e78f00aa-0d99-4611-850e-c9037ef13d10,
  abstract     = {{This paper presents a new analytical solution for the influence of regional groundwater flow on the performance of borehole heat exchangers. The solution concerns a vertical borehole. The transient thermal response for the fundamental case of a step-change in heat injection rate is given. The solution is remarkably simple and the formulas quite handy considering the complexity of the convective-diffusive heat flow process. The influence on the required borehole length for a ground-coupled heat pump is discussed.}},
  author       = {{Claesson, Johan and Hellström, Göran}},
  booktitle    = {{Proceedings : TERRASTOCK 2000, 8th International Conference on Thermal Energy Storage}},
  editor       = {{Benner, Martin}},
  isbn         = {{3-9805274-1-7}},
  keywords     = {{analytical solution; groundwater flow; ground-coupled heat pump; Borehole heat exchanger}},