Quantification of normal cerebral oxygen extraction and oxygen metabolism by phase-based MRI susceptometry: evaluation of repeatability using two different imaging protocols.
(2017) In Clinical Physiology and Functional Imaging 37(2). p.220-2011- Abstract
- Global oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) were quantified in a test-retest study. Cerebral blood flow (CBF) data, required for CMRO2 estimation, were obtained using dynamic susceptibility contrast MRI (DSC-MRI). OEF and CMRO2 were quantified using two separate data sets, that is, conventional high-resolution (HR) gradient echo (GRE) phase maps as well as echo planar imaging (EPI) phase maps taken from the baseline (precontrast) part of the DSC-MRI time series. The EPI phase data were included to elucidate whether an extra HR-GRE scan is needed to obtain information about OEF and CMRO2 , or if this information can be extracted from the DSC-MRI experiment only.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8148703
- author
- Kämpe, Robin
; Lind, Emelie
LU
; Ståhlberg, Freddy
LU
; van Westen, Danielle
LU
; Knutsson, Linda LU
and Wirestam, Ronnie LU
- organization
- publishing date
- 2017
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Clinical Physiology and Functional Imaging
- volume
- 37
- issue
- 2
- pages
- 220 - 2011
- publisher
- John Wiley & Sons Inc.
- external identifiers
-
- pmid:26490359
- scopus:84950139684
- pmid:26490359
- wos:000395108400017
- ISSN
- 1475-0961
- DOI
- 10.1111/cpf.12288
- language
- English
- LU publication?
- yes
- id
- 0d92e17e-1bbf-4ca0-a7c1-73dc80687075 (old id 8148703)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/26490359?dopt=Abstract
- date added to LUP
- 2016-04-04 08:55:24
- date last changed
- 2022-04-23 18:26:02
@article{0d92e17e-1bbf-4ca0-a7c1-73dc80687075, abstract = {{Global oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2 ) were quantified in a test-retest study. Cerebral blood flow (CBF) data, required for CMRO2 estimation, were obtained using dynamic susceptibility contrast MRI (DSC-MRI). OEF and CMRO2 were quantified using two separate data sets, that is, conventional high-resolution (HR) gradient echo (GRE) phase maps as well as echo planar imaging (EPI) phase maps taken from the baseline (precontrast) part of the DSC-MRI time series. The EPI phase data were included to elucidate whether an extra HR-GRE scan is needed to obtain information about OEF and CMRO2 , or if this information can be extracted from the DSC-MRI experiment only.}}, author = {{Kämpe, Robin and Lind, Emelie and Ståhlberg, Freddy and van Westen, Danielle and Knutsson, Linda and Wirestam, Ronnie}}, issn = {{1475-0961}}, language = {{eng}}, number = {{2}}, pages = {{220--2011}}, publisher = {{John Wiley & Sons Inc.}}, series = {{Clinical Physiology and Functional Imaging}}, title = {{Quantification of normal cerebral oxygen extraction and oxygen metabolism by phase-based MRI susceptometry: evaluation of repeatability using two different imaging protocols.}}, url = {{https://lup.lub.lu.se/search/files/8474974/5210529_.pdf}}, doi = {{10.1111/cpf.12288}}, volume = {{37}}, year = {{2017}}, }