The Lund Nuclear Microprobe sub-micron set-up. Part III: Sample stage, optical imaging and detector configuration in the experimental chamber

Elfman, Mikael LU ; Pallon, Jan LU ; Auzelyte, Vaida LU ; Kristiansson, Per LU ; Malmqvist, Klas LU ; Nilsson, Christer LU ; Shariff, Asad LU and Wegdén, Marie LU (2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.14-20
Abstract
A new sub-micron beamline for high-resolution nuclear microprobe applications has been constructed at the Lund nuclear microprobe facility. The design and construction of the main experimental chamber.. sample viewing system and computer controlled precision sample stage movement is presented in this paper. The chamber is especially designed for using a large area annular HPGe detector. The advantages with such a large area detector are discussed and illustrated. In addition the quality of the optical viewing and the precision sample stage is discussed.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
experimental chamber, nuclear microprobe, sub micron setup
in
Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
volume
231
issue
1-4
pages
14 - 20
publisher
Elsevier
external identifiers
  • wos:000229752400004
  • scopus:33644503566
ISSN
0168-583X
DOI
10.1016/j.nimb.2005.01.028
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
id
95e285bf-8b6d-4183-aa0c-75c95ab555a1 (old id 236030)
date added to LUP
2016-04-01 16:56:45
date last changed
2022-01-28 23:17:25
@article{95e285bf-8b6d-4183-aa0c-75c95ab555a1,
  abstract     = {{A new sub-micron beamline for high-resolution nuclear microprobe applications has been constructed at the Lund nuclear microprobe facility. The design and construction of the main experimental chamber.. sample viewing system and computer controlled precision sample stage movement is presented in this paper. The chamber is especially designed for using a large area annular HPGe detector. The advantages with such a large area detector are discussed and illustrated. In addition the quality of the optical viewing and the precision sample stage is discussed.}},
  author       = {{Elfman, Mikael and Pallon, Jan and Auzelyte, Vaida and Kristiansson, Per and Malmqvist, Klas and Nilsson, Christer and Shariff, Asad and Wegdén, Marie}},
  issn         = {{0168-583X}},
  keywords     = {{experimental chamber; nuclear microprobe; sub micron setup}},
  language     = {{eng}},
  number       = {{1-4}},
  pages        = {{14--20}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}},
  title        = {{The Lund Nuclear Microprobe sub-micron set-up. Part III: Sample stage, optical imaging and detector configuration in the experimental chamber}},
  url          = {{http://dx.doi.org/10.1016/j.nimb.2005.01.028}},
  doi          = {{10.1016/j.nimb.2005.01.028}},
  volume       = {{231}},
  year         = {{2005}},
}