Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

AACCI approved methods technical committee report : Collaborative study on bread volume determination by laser topography using a bread volume meter

Anderson, S. ; Purhagen, J. K. LU orcid and Bason, M. L. (2014) In Cereal Foods World 59(6). p.294-296
Abstract

Volume is an important measure of fermented bread quality that has traditionally been determined by seed displacement methods. These methods are cumbersome; poorly suited to compressible, sticky, or creased products; prone to error; and, to date, lack standardization. A collaborative study was conducted by the AACC International (AACCI) Physical Testing Methods Technical Committee in 2005 to assess the performance of a new method that uses laser topography to determine the volume of baked bread products. Eleven laboratories analyzed six Youden pairs of polyurethane bread replicas using bread volume meter (BVM) laser volumeters. Samples ranged in volume from 200 to 2,800 cm3 and included round, elongated, and rectangular... (More)

Volume is an important measure of fermented bread quality that has traditionally been determined by seed displacement methods. These methods are cumbersome; poorly suited to compressible, sticky, or creased products; prone to error; and, to date, lack standardization. A collaborative study was conducted by the AACC International (AACCI) Physical Testing Methods Technical Committee in 2005 to assess the performance of a new method that uses laser topography to determine the volume of baked bread products. Eleven laboratories analyzed six Youden pairs of polyurethane bread replicas using bread volume meter (BVM) laser volumeters. Samples ranged in volume from 200 to 2,800 cm3 and included round, elongated, and rectangular shapes. Averaged laboratory results ranged from 98.7 to 100.3% of the corresponding reference water displacement volume for each sample. Within-laboratory relative standard deviations (RSDr) ranged from 0.2 to 1.5%, and between-laboratory relative standard deviations (RSDR) ranged from 0.8 to 3.0%, indicating satisfactory performance of the method. The method has been approved as AACCI Approved Method 10-14.01.

(Less)
Please use this url to cite or link to this publication:
author
; and
publishing date
type
Contribution to journal
publication status
published
in
Cereal Foods World
volume
59
issue
6
pages
3 pages
publisher
American Association of Cereal Chemists
external identifiers
  • scopus:84916641149
ISSN
0146-6283
DOI
10.1094/CFW-59-6-0294
language
English
LU publication?
no
id
976fa34d-7992-4fce-9214-9c5097cd16d6
date added to LUP
2019-04-10 21:18:46
date last changed
2022-01-31 18:57:20
@article{976fa34d-7992-4fce-9214-9c5097cd16d6,
  abstract     = {{<p>Volume is an important measure of fermented bread quality that has traditionally been determined by seed displacement methods. These methods are cumbersome; poorly suited to compressible, sticky, or creased products; prone to error; and, to date, lack standardization. A collaborative study was conducted by the AACC International (AACCI) Physical Testing Methods Technical Committee in 2005 to assess the performance of a new method that uses laser topography to determine the volume of baked bread products. Eleven laboratories analyzed six Youden pairs of polyurethane bread replicas using bread volume meter (BVM) laser volumeters. Samples ranged in volume from 200 to 2,800 cm<sup>3</sup> and included round, elongated, and rectangular shapes. Averaged laboratory results ranged from 98.7 to 100.3% of the corresponding reference water displacement volume for each sample. Within-laboratory relative standard deviations (RSD<sub>r</sub>) ranged from 0.2 to 1.5%, and between-laboratory relative standard deviations (RSD<sub>R</sub>) ranged from 0.8 to 3.0%, indicating satisfactory performance of the method. The method has been approved as AACCI Approved Method 10-14.01.</p>}},
  author       = {{Anderson, S. and Purhagen, J. K. and Bason, M. L.}},
  issn         = {{0146-6283}},
  language     = {{eng}},
  month        = {{01}},
  number       = {{6}},
  pages        = {{294--296}},
  publisher    = {{American Association of Cereal Chemists}},
  series       = {{Cereal Foods World}},
  title        = {{AACCI approved methods technical committee report : Collaborative study on bread volume determination by laser topography using a bread volume meter}},
  url          = {{http://dx.doi.org/10.1094/CFW-59-6-0294}},
  doi          = {{10.1094/CFW-59-6-0294}},
  volume       = {{59}},