Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Experimental investigation of the shear force capacity of prismatic cross laminated timber beams

Danielsson, Henrik LU orcid ; Pazlar, Tomaž ; Serrano, Erik LU orcid and Azinović, Boris (2024) In Engineering Structures 308.
Abstract

Experimental tests of Cross Laminated Timber (CLT) under in-plane beam loading conditions are presented. The influence of the element layup, the individual lamination width, and the beam overhang at the supports on the shear force capacity was investigated. All the CLT beams had the same gross cross section, and a 4-point-bending test setup was used. The experimentally determined load-bearing capacities are compared with the load-bearing capacities resulting from analytical methods proposed for structural design, focusing on shear failure in the crossing areas of flatwise bonded laminations (shear failure mode III). The test results indicate no or very small influence of the element layup and the lamination width on the shear force... (More)

Experimental tests of Cross Laminated Timber (CLT) under in-plane beam loading conditions are presented. The influence of the element layup, the individual lamination width, and the beam overhang at the supports on the shear force capacity was investigated. All the CLT beams had the same gross cross section, and a 4-point-bending test setup was used. The experimentally determined load-bearing capacities are compared with the load-bearing capacities resulting from analytical methods proposed for structural design, focusing on shear failure in the crossing areas of flatwise bonded laminations (shear failure mode III). The test results indicate no or very small influence of the element layup and the lamination width on the shear force capacity. These results partly contradict the predictions of the proposed design methods. Of the three studied beam geometry parameters, the beam overhang at the support had the greatest influence on the load-bearing capacity.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Beam, CLT, Cross laminated timber, Design methods, Shear capacity, Shear failure mode III, Testing
in
Engineering Structures
volume
308
article number
117889
publisher
Elsevier
external identifiers
  • scopus:85189547705
ISSN
0141-0296
DOI
10.1016/j.engstruct.2024.117889
language
English
LU publication?
yes
id
98af7709-d568-4640-b80d-6590d85a6206
date added to LUP
2024-04-23 11:35:27
date last changed
2024-04-23 11:36:04
@article{98af7709-d568-4640-b80d-6590d85a6206,
  abstract     = {{<p>Experimental tests of Cross Laminated Timber (CLT) under in-plane beam loading conditions are presented. The influence of the element layup, the individual lamination width, and the beam overhang at the supports on the shear force capacity was investigated. All the CLT beams had the same gross cross section, and a 4-point-bending test setup was used. The experimentally determined load-bearing capacities are compared with the load-bearing capacities resulting from analytical methods proposed for structural design, focusing on shear failure in the crossing areas of flatwise bonded laminations (shear failure mode III). The test results indicate no or very small influence of the element layup and the lamination width on the shear force capacity. These results partly contradict the predictions of the proposed design methods. Of the three studied beam geometry parameters, the beam overhang at the support had the greatest influence on the load-bearing capacity.</p>}},
  author       = {{Danielsson, Henrik and Pazlar, Tomaž and Serrano, Erik and Azinović, Boris}},
  issn         = {{0141-0296}},
  keywords     = {{Beam; CLT; Cross laminated timber; Design methods; Shear capacity; Shear failure mode III; Testing}},
  language     = {{eng}},
  publisher    = {{Elsevier}},
  series       = {{Engineering Structures}},
  title        = {{Experimental investigation of the shear force capacity of prismatic cross laminated timber beams}},
  url          = {{http://dx.doi.org/10.1016/j.engstruct.2024.117889}},
  doi          = {{10.1016/j.engstruct.2024.117889}},
  volume       = {{308}},