Towards energy efficient heating in industrial processes - Three steps to achieve maximized efficiency in an induction heating system

Siesing, Leif LU ; Lundström, Fredrik LU ; Frogner, Kenneth LU ; Cedell, Tord LU and Andersson, Mats LU (2018) 25. p.404-411
Abstract
The demand for energy efficient heating solutions can be met by a new concept technology of induction heating. The concept technology relies on inductors built on litz wires moulded in soft magnetic composite. The aim of this article is to present and verify a hypothesis for greatly improved induction heating efficiency when modifying a traditional inductor design. The verification performed using analytical solutions, FEM simulations and experimental work, clearly shows higher heating efficiency compared to traditional heating inductors. The work also shows a significant reduction of magnetic stray field when flux concentrator is used, given a certain heating power.
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Induction heating, Industrial heating, Energy efficiency, SMC, Litz, Magnetic stray field
host publication
Procedia Manufacturing : Proceedings of the 8th Swedish Production Symposium (SPS 2018) - Proceedings of the 8th Swedish Production Symposium (SPS 2018)
volume
25
pages
8 pages
external identifiers
  • scopus:85065674925
DOI
10.1016/j.promfg.2018.06.110
project
Induction heating of carbon fibre reinforced polymer composites
language
English
LU publication?
yes
id
a4e43ad4-333e-4291-96b9-d59b6191761d
date added to LUP
2018-08-13 09:48:50
date last changed
2022-03-25 03:21:54
@inproceedings{a4e43ad4-333e-4291-96b9-d59b6191761d,
  abstract     = {{The demand for energy efficient heating solutions can be met by a new concept technology of induction heating. The concept technology relies on inductors built on litz wires moulded in soft magnetic composite. The aim of this article is to present and verify a hypothesis for greatly improved induction heating efficiency when modifying a traditional inductor design. The verification performed using analytical solutions, FEM simulations and experimental work, clearly shows higher heating efficiency compared to traditional heating inductors. The work also shows a significant reduction of magnetic stray field when flux concentrator is used, given a certain heating power.}},
  author       = {{Siesing, Leif and Lundström, Fredrik and Frogner, Kenneth and Cedell, Tord and Andersson, Mats}},
  booktitle    = {{Procedia Manufacturing : Proceedings of the 8th Swedish Production Symposium (SPS 2018)}},
  keywords     = {{Induction heating; Industrial heating; Energy efficiency; SMC; Litz; Magnetic stray field}},
  language     = {{eng}},
  month        = {{07}},
  pages        = {{404--411}},
  title        = {{Towards energy efficient heating in industrial processes - Three steps to achieve maximized efficiency in an induction heating system}},
  url          = {{http://dx.doi.org/10.1016/j.promfg.2018.06.110}},
  doi          = {{10.1016/j.promfg.2018.06.110}},
  volume       = {{25}},