Heat exchanger network optimisation considering different shell-side flow arrangements

Li, Nianqi LU ; Klemeš, Jiří Jaromír ; Sunden, Bengt LU ; Wang, Qiuwang and Zeng, Min (2022) In Energy 261.
Abstract

Heat exchanger network synthesis (HENS) is an effective tool for heat recovery in chemical and petrochemical industries. This study aims to show a method for HENS with the consideration of different shell-side flow arrangements in shell-and-tube heat exchangers. The proposed MINLP model is modified from the stage-wise superstructure model, incorporating newly developed correlations for shell-side pressure drop calculation for the helical baffle. The objective is to minimise the total annual cost (TAC) with a trade-off between the cost of different shell-side heat exchangers, utility cost, and pumping cost. The selection of baffle design is decided by the saved pumping cost and the increased area cost. The proposed model is tested from... (More)

Heat exchanger network synthesis (HENS) is an effective tool for heat recovery in chemical and petrochemical industries. This study aims to show a method for HENS with the consideration of different shell-side flow arrangements in shell-and-tube heat exchangers. The proposed MINLP model is modified from the stage-wise superstructure model, incorporating newly developed correlations for shell-side pressure drop calculation for the helical baffle. The objective is to minimise the total annual cost (TAC) with a trade-off between the cost of different shell-side heat exchangers, utility cost, and pumping cost. The selection of baffle design is decided by the saved pumping cost and the increased area cost. The proposed model is tested from different points of view: with/without utility constraints and different statuses of the streams. Three case studies are presented and compared with the results from the literature. The proposed method with different shell-side baffles can reduce the heat transfer area and pressure drop. For fixed utility consumptions, the TAC in a case study is decreased by 8.9% with mixed baffle types. Although the unit per area cost of the helical baffle is higher than the segmental baffle, the increased investment cost could be compensated by the reduced operation cost, especially for plants with high viscosity streams and long-term cost-saving.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Heat exchanger network, Mathematical programming, Optimisation, Pressure drop, Shell-and-tube heat exchanger
in
Energy
volume
261
article number
125081
publisher
Elsevier
external identifiers
  • scopus:85137043385
ISSN
0360-5442
DOI
10.1016/j.energy.2022.125081
language
English
LU publication?
yes
id
b8c65758-a288-43aa-b5cd-9f14b4b4c848
date added to LUP
2022-10-14 11:29:01
date last changed
2023-11-21 12:12:48
@article{b8c65758-a288-43aa-b5cd-9f14b4b4c848,
  abstract     = {{<p>Heat exchanger network synthesis (HENS) is an effective tool for heat recovery in chemical and petrochemical industries. This study aims to show a method for HENS with the consideration of different shell-side flow arrangements in shell-and-tube heat exchangers. The proposed MINLP model is modified from the stage-wise superstructure model, incorporating newly developed correlations for shell-side pressure drop calculation for the helical baffle. The objective is to minimise the total annual cost (TAC) with a trade-off between the cost of different shell-side heat exchangers, utility cost, and pumping cost. The selection of baffle design is decided by the saved pumping cost and the increased area cost. The proposed model is tested from different points of view: with/without utility constraints and different statuses of the streams. Three case studies are presented and compared with the results from the literature. The proposed method with different shell-side baffles can reduce the heat transfer area and pressure drop. For fixed utility consumptions, the TAC in a case study is decreased by 8.9% with mixed baffle types. Although the unit per area cost of the helical baffle is higher than the segmental baffle, the increased investment cost could be compensated by the reduced operation cost, especially for plants with high viscosity streams and long-term cost-saving.</p>}},
  author       = {{Li, Nianqi and Klemeš, Jiří Jaromír and Sunden, Bengt and Wang, Qiuwang and Zeng, Min}},
  issn         = {{0360-5442}},
  keywords     = {{Heat exchanger network; Mathematical programming; Optimisation; Pressure drop; Shell-and-tube heat exchanger}},
  language     = {{eng}},
  month        = {{12}},
  publisher    = {{Elsevier}},
  series       = {{Energy}},
  title        = {{Heat exchanger network optimisation considering different shell-side flow arrangements}},
  url          = {{http://dx.doi.org/10.1016/j.energy.2022.125081}},
  doi          = {{10.1016/j.energy.2022.125081}},
  volume       = {{261}},
  year         = {{2022}},
}