Design of a Pediatric Rectal Ultrasound Probe Intended for Ultra-High Frequency Ultrasound Diagnostics

Evertsson, Maria LU ; Graneli, Christina LU ; Vernersson, Alvina ; Wiaczek, Olivia ; Hagelsteen, Kristine LU orcid ; Erlöv, Tobias LU ; Cinthio, Magnus LU and Stenström, Pernilla LU orcid (2023) In Diagnostics 13(10).
Abstract

It has been shown that ultra-high frequency (UHF) ultrasound applied to the external bowel wall can delineate the histo-anatomic layers in detail and distinguish normal bowel from aganglionosis. This would potentially reduce or lessen the need for biopsies that are currently mandatory for the diagnosis of Hirschsprung’s disease. However, to our knowledge, no suitable rectal probes for such a use are on the market. The aim was to define the specifications of an UHF transrectal ultrasound probe (50 MHz center frequency) suitable for use in infants. Probe requirements according to patient anatomy, clinicians’ requests, and biomedical engineering UHF prerequisites were collected within an expert group. Suitable probes on the market and in... (More)

It has been shown that ultra-high frequency (UHF) ultrasound applied to the external bowel wall can delineate the histo-anatomic layers in detail and distinguish normal bowel from aganglionosis. This would potentially reduce or lessen the need for biopsies that are currently mandatory for the diagnosis of Hirschsprung’s disease. However, to our knowledge, no suitable rectal probes for such a use are on the market. The aim was to define the specifications of an UHF transrectal ultrasound probe (50 MHz center frequency) suitable for use in infants. Probe requirements according to patient anatomy, clinicians’ requests, and biomedical engineering UHF prerequisites were collected within an expert group. Suitable probes on the market and in clinical use were reviewed. The requirements were transferred into the sketching of potential UHF ultrasound transrectal probes followed by their 3D prototype printing. Two prototypes were created and tested by five pediatric surgeons. The larger and straight 8 mm head and shaft probe was preferred as it facilitated stability, ease of anal insertion, and possible UHF technique including 128 piezoelectric elements in a linear array. We hereby present the procedure and considerations behind the development of a proposed new UHF transrectal pediatric probe. Such a device can open new possibilities for the diagnostics of pediatric anorectal conditions.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
anorectal conditions, diagnosis, Hirschsprung’s disease, pediatrics, probe, ultra-high frequency ultrasound
in
Diagnostics
volume
13
issue
10
article number
1667
publisher
MDPI AG
external identifiers
  • pmid:37238152
  • scopus:85160539028
ISSN
2075-4418
DOI
10.3390/diagnostics13101667
language
English
LU publication?
yes
additional info
Publisher Copyright: © 2023 by the authors.
id
c94dd67e-ca90-4059-bacb-ac2a6659a5e6
date added to LUP
2023-07-28 21:28:59
date last changed
2024-04-19 23:59:34
@article{c94dd67e-ca90-4059-bacb-ac2a6659a5e6,
  abstract     = {{<p>It has been shown that ultra-high frequency (UHF) ultrasound applied to the external bowel wall can delineate the histo-anatomic layers in detail and distinguish normal bowel from aganglionosis. This would potentially reduce or lessen the need for biopsies that are currently mandatory for the diagnosis of Hirschsprung’s disease. However, to our knowledge, no suitable rectal probes for such a use are on the market. The aim was to define the specifications of an UHF transrectal ultrasound probe (50 MHz center frequency) suitable for use in infants. Probe requirements according to patient anatomy, clinicians’ requests, and biomedical engineering UHF prerequisites were collected within an expert group. Suitable probes on the market and in clinical use were reviewed. The requirements were transferred into the sketching of potential UHF ultrasound transrectal probes followed by their 3D prototype printing. Two prototypes were created and tested by five pediatric surgeons. The larger and straight 8 mm head and shaft probe was preferred as it facilitated stability, ease of anal insertion, and possible UHF technique including 128 piezoelectric elements in a linear array. We hereby present the procedure and considerations behind the development of a proposed new UHF transrectal pediatric probe. Such a device can open new possibilities for the diagnostics of pediatric anorectal conditions.</p>}},
  author       = {{Evertsson, Maria and Graneli, Christina and Vernersson, Alvina and Wiaczek, Olivia and Hagelsteen, Kristine and Erlöv, Tobias and Cinthio, Magnus and Stenström, Pernilla}},
  issn         = {{2075-4418}},
  keywords     = {{anorectal conditions; diagnosis; Hirschsprung’s disease; pediatrics; probe; ultra-high frequency ultrasound}},
  language     = {{eng}},
  number       = {{10}},
  publisher    = {{MDPI AG}},
  series       = {{Diagnostics}},
  title        = {{Design of a Pediatric Rectal Ultrasound Probe Intended for Ultra-High Frequency Ultrasound Diagnostics}},
  url          = {{http://dx.doi.org/10.3390/diagnostics13101667}},
  doi          = {{10.3390/diagnostics13101667}},
  volume       = {{13}},
  year         = {{2023}},
}