- A directly cooled winding in an electrical machine
is an appealing solution for a traction application when the
electrical machine is operating near peak power for extended
periods of time. This directly cooled winding is based on a
laminated structure where the power losses in the conducting
strips are instantly dissipated by an air-flow between the strips.
As an outcome, the hottest component of the electrical machine –
the windings are directly cooled, which in turn improves the
thermal management of electrical machines, boost up their peak
torque and power, reduces their size and suits them better for the
specific application. This paper focuses... (More) - A directly cooled winding in an electrical machine
is an appealing solution for a traction application when the
electrical machine is operating near peak power for extended
periods of time. This directly cooled winding is based on a
laminated structure where the power losses in the conducting
strips are instantly dissipated by an air-flow between the strips.
As an outcome, the hottest component of the electrical machine –
the windings are directly cooled, which in turn improves the
thermal management of electrical machines, boost up their peak
torque and power, reduces their size and suits them better for the
specific application. This paper focuses on the key structure of
the machine construction – a direct air cooled laminated winding
segment for a PMSM with distributed concentrated windings.
The AC losses and heat transfer of the laminated windings are
presented with production experiences on winding segments. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8052873
- author
- Reinap, Avo LU ; Högmark, Conny LU ; Frogner, Kenneth LU ; Lundström, Fredrik LU ; Andersson, Mats LU ; Alaküla, Mats LU and Wang, Lei LU
- organization
- publishing date
- 2015
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- [Host publication title missing]
- conference name
- 5th International Electric Drives Production Conference (E|DPC)
- conference location
- Nuremberg, Germany
- conference dates
- 2015-09-15 - 2015-09-16
- ISBN
- 978-1-4673-7511-5
- language
- English
- LU publication?
- yes
- id
- edf05afb-aaa5-4363-81ef-cc5e61a19900 (old id 8052873)
- date added to LUP
- 2016-04-04 13:20:44
- date last changed
- 2018-11-21 21:13:22
@inproceedings{edf05afb-aaa5-4363-81ef-cc5e61a19900, abstract = {{A directly cooled winding in an electrical machine<br/><br> is an appealing solution for a traction application when the<br/><br> electrical machine is operating near peak power for extended<br/><br> periods of time. This directly cooled winding is based on a<br/><br> laminated structure where the power losses in the conducting<br/><br> strips are instantly dissipated by an air-flow between the strips.<br/><br> As an outcome, the hottest component of the electrical machine –<br/><br> the windings are directly cooled, which in turn improves the<br/><br> thermal management of electrical machines, boost up their peak<br/><br> torque and power, reduces their size and suits them better for the<br/><br> specific application. This paper focuses on the key structure of<br/><br> the machine construction – a direct air cooled laminated winding<br/><br> segment for a PMSM with distributed concentrated windings.<br/><br> The AC losses and heat transfer of the laminated windings are<br/><br> presented with production experiences on winding segments.}}, author = {{Reinap, Avo and Högmark, Conny and Frogner, Kenneth and Lundström, Fredrik and Andersson, Mats and Alaküla, Mats and Wang, Lei}}, booktitle = {{[Host publication title missing]}}, isbn = {{978-1-4673-7511-5}}, language = {{eng}}, title = {{Electrical Machine Design with Directly Cooled Laminated Fractional Pitch Windings}}, year = {{2015}}, }