Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
(2015) In Medical Physics 42(12). p.6895-6911- Abstract
 - The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c).
 
    Please use this url to cite or link to this publication:
    https://lup.lub.lu.se/record/8505702
- author
 - organization
 - publishing date
 - 2015
 - type
 - Contribution to journal
 - publication status
 - published
 - subject
 - in
 - Medical Physics
 - volume
 - 42
 - issue
 - 12
 - pages
 - 6895 - 6911
 - publisher
 - John Wiley & Sons Inc.
 - external identifiers
 - 
                
- pmid:26632046
 - wos:000368244100013
 - scopus:84947447609
 - pmid:26632046
 
 - ISSN
 - 0094-2405
 - DOI
 - 10.1118/1.4934830
 - language
 - English
 - LU publication?
 - yes
 - id
 - ff4cf8df-095f-436c-8e80-b102a0c42044 (old id 8505702)
 - alternative location
 - http://www.ncbi.nlm.nih.gov/pubmed/26632046?dopt=Abstract
 - date added to LUP
 - 2016-04-01 13:08:51
 - date last changed
 - 2025-10-14 09:07:26
 
@article{ff4cf8df-095f-436c-8e80-b102a0c42044,
  abstract     = {{The energy spectrum for a cadmium zinc telluride (CZT) detector has a low energy tail due to incomplete charge collection and intercrystal scattering. Due to these solid-state detector effects, scatter would be overestimated if the conventional triple-energy window (TEW) method is used for scatter and crosstalk corrections in CZT-based imaging systems. The objective of this work is to develop a scatter and crosstalk correction method for (99m)Tc/(123)I dual-radionuclide imaging for a CZT-based dedicated cardiac SPECT system with pinhole collimators (GE Discovery NM 530c/570c).}},
  author       = {{Fan, Peng and Hutton, Brian F and Holstensson, Maria and Ljungberg, Michael and Hendrik Pretorius, P and Prasad, Rameshwar and Ma, Tianyu and Liu, Yaqiang and Wang, Shi and Thorn, Stephanie L and Stacy, Mitchel R and Sinusas, Albert J and Liu, Chi}},
  issn         = {{0094-2405}},
  language     = {{eng}},
  number       = {{12}},
  pages        = {{6895--6911}},
  publisher    = {{John Wiley & Sons Inc.}},
  series       = {{Medical Physics}},
  title        = {{Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.}},
  url          = {{http://dx.doi.org/10.1118/1.4934830}},
  doi          = {{10.1118/1.4934830}},
  volume       = {{42}},
  year         = {{2015}},
}