Sensor Calibration Models for a Non-Invasive Blood Glucose Measurement Sensor

Stemmann, Meike LU ; Ståhl, Fredrik LU ; Lallemand, Jordane ; Renard, Eric and Johansson, Rolf LU orcid (2010) Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2010 p.4979-4982
Abstract
A calibration model was developed for a non-invasive blood glucose sensor, to determine how the blood glucose data measured by this sensor is related to blood glucose data measured with laboratory capillary finger sticks and to corrupting noise. The variability of calibration models for different patients was analyzed as well as the dynamics of the non-invasive blood glucose sensor according to reference blood glucose measurements and corrupting noise.
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
calibration model, blood glucose sensor
host publication
Annual International Conference of the IEEE Engineering in Medicine and Biology Society
pages
4979 - 4982
publisher
IEEE - Institute of Electrical and Electronics Engineers Inc.
conference name
Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2010
conference location
Buenos Aires, Argentina
conference dates
2010-08-31 - 2010-09-04
external identifiers
  • wos:000287964005092
  • scopus:78650843921
  • pmid:21096677
ISSN
1557-170X
ISBN
978-1-4244-4123-5
DOI
10.1109/IEMBS.2010.5627226
project
DIAdvisor
language
English
LU publication?
yes
id
24d20661-e98e-488a-a449-068dcbb2a28a (old id 1774630)
date added to LUP
2016-04-01 14:43:21
date last changed
2022-01-28 02:09:16
@inproceedings{24d20661-e98e-488a-a449-068dcbb2a28a,
  abstract     = {{A calibration model was developed for a non-invasive blood glucose sensor, to determine how the blood glucose data measured by this sensor is related to blood glucose data measured with laboratory capillary finger sticks and to corrupting noise. The variability of calibration models for different patients was analyzed as well as the dynamics of the non-invasive blood glucose sensor according to reference blood glucose measurements and corrupting noise.}},
  author       = {{Stemmann, Meike and Ståhl, Fredrik and Lallemand, Jordane and Renard, Eric and Johansson, Rolf}},
  booktitle    = {{Annual International Conference of the IEEE Engineering in Medicine and Biology Society}},
  isbn         = {{978-1-4244-4123-5}},
  issn         = {{1557-170X}},
  keywords     = {{calibration model; blood glucose sensor}},
  language     = {{eng}},
  pages        = {{4979--4982}},
  publisher    = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}},
  title        = {{Sensor Calibration Models for a Non-Invasive Blood Glucose Measurement Sensor}},
  url          = {{http://dx.doi.org/10.1109/IEMBS.2010.5627226}},
  doi          = {{10.1109/IEMBS.2010.5627226}},
  year         = {{2010}},
}