Combined diffusion weighting and CSF suppression in functional MRI.

Knutsson, Linda LU orcid ; Bolling, Max ; Wirestam, Ronnie LU orcid ; Holtås, Stig LU and Ståhlberg, Freddy LU (2002) In NMR in Biomedicine 15(3). p.235-240
Abstract
In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by... (More)
In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal-to-noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 +/- 73 pixels (mean +/- SD) using the standard EPI pulse sequence, 31 +/- 12 pixels using IR-EPI and 15 +/- 13 pixels when DW-IR-EPI was employed. The relative signal increase was 5.7 +/- 1.1% using standard EPI, 11.5 +/- 3.1% using IR-EPI and 9.9 +/- 2.4% using DW-IR-EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 +/- 50 pixels using the standard EPI, and when using IR-EPI, the activated volume was 28 +/- 13 pixels. At equal S/N, the signal increase was 7.3 +/- 1.4% using standard EPI and 12.0 +/- 3.6% using IR-EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
NMR in Biomedicine
volume
15
issue
3
pages
235 - 240
publisher
John Wiley & Sons Inc.
external identifiers
  • wos:000175538900005
  • pmid:11968139
  • scopus:0036094762
ISSN
0952-3480
DOI
10.1002/nbm.767
language
English
LU publication?
yes
id
691d3a0d-ee82-450c-a26b-3dce99e1e27a (old id 108444)
alternative location
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=11968139&dopt=Abstract
date added to LUP
2016-04-01 11:35:46
date last changed
2022-02-25 18:34:41
@article{691d3a0d-ee82-450c-a26b-3dce99e1e27a,
  abstract     = {{In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo-planar imaging (IR-EPI) pulse sequence and one IR-EPI with additional diffusion weighting (DW-IR-EPI) were developed and compared to a standard gradient-echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi-complex finger-tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal-to-noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 +/- 73 pixels (mean +/- SD) using the standard EPI pulse sequence, 31 +/- 12 pixels using IR-EPI and 15 +/- 13 pixels when DW-IR-EPI was employed. The relative signal increase was 5.7 +/- 1.1% using standard EPI, 11.5 +/- 3.1% using IR-EPI and 9.9 +/- 2.4% using DW-IR-EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 +/- 50 pixels using the standard EPI, and when using IR-EPI, the activated volume was 28 +/- 13 pixels. At equal S/N, the signal increase was 7.3 +/- 1.4% using standard EPI and 12.0 +/- 3.6% using IR-EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels.}},
  author       = {{Knutsson, Linda and Bolling, Max and Wirestam, Ronnie and Holtås, Stig and Ståhlberg, Freddy}},
  issn         = {{0952-3480}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{235--240}},
  publisher    = {{John Wiley & Sons Inc.}},
  series       = {{NMR in Biomedicine}},
  title        = {{Combined diffusion weighting and CSF suppression in functional MRI.}},
  url          = {{http://dx.doi.org/10.1002/nbm.767}},
  doi          = {{10.1002/nbm.767}},
  volume       = {{15}},
  year         = {{2002}},
}