An off-axis STIM procedure for precise mass determination and imaging
(2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.988-993- Abstract
- For the precise determination of the local mass density in thin samples analysed at the Lund Nuclear Microprobe, a modified version of off-axis STIM is described. An on-axis/off-axis geometry is used where a thin C-foil, placed behind the sample scatters protons into the particle detector. The advantage of this geometry compared to the off-axis case where particles are directly scattered from the sample into the particle detector is that the energy-loss spectrum acquired is less degraded. A spectral resolution comparable to on-axis STIM is achieved at a beam current high enough to allow for a simultaneous PIXE analysis (50-100 pA). (C) 2004 Elsevier B.V. All rights reserved.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/275171
- author
- Pallon, Jan LU ; Auzelyte, Vaida LU ; Elfman, Mikael LU ; Garmer, M ; Kristiansson, Per LU ; Malmqvist, Klas LU ; Nilsson, Christer LU ; Shariff, Asad LU and Wegdén, Marie LU
- organization
- publishing date
- 2004
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- PIXE, imaging, nuclear microprobe, mass normalization, STIM
- in
- Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
- volume
- 219-20
- pages
- 988 - 993
- publisher
- Elsevier
- external identifiers
-
- wos:000221895800186
- scopus:2342477771
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2004.01.201
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
- id
- de6f9881-0d6c-456f-bcd0-d0f42f56567a (old id 275171)
- date added to LUP
- 2016-04-01 16:23:54
- date last changed
- 2022-01-28 19:23:16
@article{de6f9881-0d6c-456f-bcd0-d0f42f56567a, abstract = {{For the precise determination of the local mass density in thin samples analysed at the Lund Nuclear Microprobe, a modified version of off-axis STIM is described. An on-axis/off-axis geometry is used where a thin C-foil, placed behind the sample scatters protons into the particle detector. The advantage of this geometry compared to the off-axis case where particles are directly scattered from the sample into the particle detector is that the energy-loss spectrum acquired is less degraded. A spectral resolution comparable to on-axis STIM is achieved at a beam current high enough to allow for a simultaneous PIXE analysis (50-100 pA). (C) 2004 Elsevier B.V. All rights reserved.}}, author = {{Pallon, Jan and Auzelyte, Vaida and Elfman, Mikael and Garmer, M and Kristiansson, Per and Malmqvist, Klas and Nilsson, Christer and Shariff, Asad and Wegdén, Marie}}, issn = {{0168-583X}}, keywords = {{PIXE; imaging; nuclear microprobe; mass normalization; STIM}}, language = {{eng}}, pages = {{988--993}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms}}, title = {{An off-axis STIM procedure for precise mass determination and imaging}}, url = {{http://dx.doi.org/10.1016/j.nimb.2004.01.201}}, doi = {{10.1016/j.nimb.2004.01.201}}, volume = {{219-20}}, year = {{2004}}, }