Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

New experimental setup to use ellipsometry to study liquid-liquid and liquid-solid interfaces

Benjamins, Jan-Willem LU ; Jönsson, Bengt LU ; Thuresson, Krister LU and Nylander, Tommy LU (2002) In Langmuir 18(16). p.6437-6444
Abstract
Different types of optical light guides were constructed and tested to enable convenient multiple angle of incidence ellipsometry, on solid and liquid interfaces in liquid solutions. Two light guides are needed on an ellipsometer, one to guide the incoming light and one to guide the light that is reflected at the test surface, and therefore one light guide was mounted on the laser arm and one on the detector arm of the ellipsometer. With this arrangement the optical windows automatically adjust to always be perpendicular to the direction of the light independent of the angle of incidence. The purpose with these light guides is to facilitate the passage of light through the air/solution interface. A thorough theoretical and experimental... (More)
Different types of optical light guides were constructed and tested to enable convenient multiple angle of incidence ellipsometry, on solid and liquid interfaces in liquid solutions. Two light guides are needed on an ellipsometer, one to guide the incoming light and one to guide the light that is reflected at the test surface, and therefore one light guide was mounted on the laser arm and one on the detector arm of the ellipsometer. With this arrangement the optical windows automatically adjust to always be perpendicular to the direction of the light independent of the angle of incidence. The purpose with these light guides is to facilitate the passage of light through the air/solution interface. A thorough theoretical and experimental analysis of optical errors introduced by such light guides is presented. This discussion includes the effect of multiple reflections between and within the windows of the light guides' On the basis of this analysis a new ellipsometry setup with light guides, consisting of glass tube's with glued end windows, was developed. This setup makes it possible to perform accurate measurements in almost any type of measuring cell at any angle of incidence. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Langmuir
volume
18
issue
16
pages
6437 - 6444
publisher
The American Chemical Society (ACS)
external identifiers
  • wos:000177224400071
  • scopus:0037031441
ISSN
0743-7463
DOI
10.1021/la025588x
language
English
LU publication?
yes
id
cd00bb9e-f2b2-4b40-8782-05be83b4d20c (old id 331939)
date added to LUP
2016-04-01 11:53:21
date last changed
2022-01-26 19:42:48
@article{cd00bb9e-f2b2-4b40-8782-05be83b4d20c,
  abstract     = {{Different types of optical light guides were constructed and tested to enable convenient multiple angle of incidence ellipsometry, on solid and liquid interfaces in liquid solutions. Two light guides are needed on an ellipsometer, one to guide the incoming light and one to guide the light that is reflected at the test surface, and therefore one light guide was mounted on the laser arm and one on the detector arm of the ellipsometer. With this arrangement the optical windows automatically adjust to always be perpendicular to the direction of the light independent of the angle of incidence. The purpose with these light guides is to facilitate the passage of light through the air/solution interface. A thorough theoretical and experimental analysis of optical errors introduced by such light guides is presented. This discussion includes the effect of multiple reflections between and within the windows of the light guides' On the basis of this analysis a new ellipsometry setup with light guides, consisting of glass tube's with glued end windows, was developed. This setup makes it possible to perform accurate measurements in almost any type of measuring cell at any angle of incidence.}},
  author       = {{Benjamins, Jan-Willem and Jönsson, Bengt and Thuresson, Krister and Nylander, Tommy}},
  issn         = {{0743-7463}},
  language     = {{eng}},
  number       = {{16}},
  pages        = {{6437--6444}},
  publisher    = {{The American Chemical Society (ACS)}},
  series       = {{Langmuir}},
  title        = {{New experimental setup to use ellipsometry to study liquid-liquid and liquid-solid interfaces}},
  url          = {{http://dx.doi.org/10.1021/la025588x}},
  doi          = {{10.1021/la025588x}},
  volume       = {{18}},
  year         = {{2002}},
}