Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Power swing damping in Iceland based on phasor measurements

Samuelsson, Olof LU ; Johannsdottir, H. ; Gustavsson, N. ; Hrafnsson, T. ; Karlsson, D. ; Salj, J. and Sollie, A. (2002) 2002 International Conference on Power System Protection p.23-28
Abstract
Phasor measurement signals are used as only input to a wide-area power system stabilizer to increase interarea mode damping of the Icelandic system. Modal analysis and time simulations of a detailed model show that frequency difference as PSS input gives a damping improvement that is robust to drastic changes in system topology. Field data from phasor measurement units indicate high signal quality and that frequency difference is realistic as PSS input. The wide-area PSS is compared against a generic local PSS with shaft speed input. The total performance is comparable, but while the local PSS has better local mode damping, frequency difference appears to give better interarea mode observability. Continued work aims at combining these... (More)
Phasor measurement signals are used as only input to a wide-area power system stabilizer to increase interarea mode damping of the Icelandic system. Modal analysis and time simulations of a detailed model show that frequency difference as PSS input gives a damping improvement that is robust to drastic changes in system topology. Field data from phasor measurement units indicate high signal quality and that frequency difference is realistic as PSS input. The wide-area PSS is compared against a generic local PSS with shaft speed input. The total performance is comparable, but while the local PSS has better local mode damping, frequency difference appears to give better interarea mode observability. Continued work aims at combining these advantages in a PSS that uses both local and wide-area signals (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
high signal quality, field data, damping improvement, PSS input, frequency difference, time simulations, modal analysis, Icelandic system, interarea mode damping, wide-area power system stabilizer, phasor measurements signals, power swing damping, Iceland based, shaft speed input, total performance, local mode damping, interarea mode observability
host publication
Proceedings of the 13th International Conference on Power System Protection. PSP 2002
pages
23 - 28
publisher
Univ. Ljubljana
conference name
2002 International Conference on Power System Protection
conference location
Bled, Slovenia
conference dates
2002-09-25 - 2002-09-27
language
English
LU publication?
yes
id
ecf6a9e7-edce-4281-bc95-1d742c7b1556 (old id 610835)
date added to LUP
2016-04-04 10:29:05
date last changed
2018-11-21 20:59:02
@inproceedings{ecf6a9e7-edce-4281-bc95-1d742c7b1556,
  abstract     = {{Phasor measurement signals are used as only input to a wide-area power system stabilizer to increase interarea mode damping of the Icelandic system. Modal analysis and time simulations of a detailed model show that frequency difference as PSS input gives a damping improvement that is robust to drastic changes in system topology. Field data from phasor measurement units indicate high signal quality and that frequency difference is realistic as PSS input. The wide-area PSS is compared against a generic local PSS with shaft speed input. The total performance is comparable, but while the local PSS has better local mode damping, frequency difference appears to give better interarea mode observability. Continued work aims at combining these advantages in a PSS that uses both local and wide-area signals}},
  author       = {{Samuelsson, Olof and Johannsdottir, H. and Gustavsson, N. and Hrafnsson, T. and Karlsson, D. and Salj, J. and Sollie, A.}},
  booktitle    = {{Proceedings of the 13th International Conference on Power System Protection. PSP 2002}},
  keywords     = {{high signal quality; field data; damping improvement; PSS input; frequency difference; time simulations; modal analysis; Icelandic system; interarea mode damping; wide-area power system stabilizer; phasor measurements signals; power swing damping; Iceland based; shaft speed input; total performance; local mode damping; interarea mode observability}},
  language     = {{eng}},
  pages        = {{23--28}},
  publisher    = {{Univ. Ljubljana}},
  title        = {{Power swing damping in Iceland based on phasor measurements}},
  year         = {{2002}},
}