Optical parametric oscillator based lidar system applied to atomic mercury monitoring
(2003) 2003 Conference on Lasers and Electro-Optics Europe (CLEO/Europe 2003) p.471-471- Abstract
- Field measurements of mercury emissions has been performed by using a mobile lidar system. In this system an Nd:YAG-pumped OPO (Optical Parametric Oscillator) laser system is employed to generate a narrow band (better than 0.2 cm<sup>-1</sup>) UV beam at the mercury resonance absorption line at 253.65 nm. An inter-comparison of the lidar system and two different point monitoring systems has been performed showing excellent agreement between the instruments
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/612266
- author
- Sjöholm, Mikael LU ; Weibring, Petter LU ; Edner, Hans LU and Svanberg, Sune LU
- organization
- publishing date
- 2003
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- UV beam generation, OPO, atomic mercury monitoring, optical parametric oscillator, field measurements, mercury emissions, mobile lidar system, pumping, Nd:YAG, 253.65 nm, Hg, YAG:Nd, YAl5O12:Nd
- host publication
- 2003 Conference on Lasers and Electro-Optics Europe (CLEO/Europe 2003) (IEEE Cat. No.03TH8666)
- pages
- 471 - 471
- publisher
- IEEE - Institute of Electrical and Electronics Engineers Inc.
- conference name
- 2003 Conference on Lasers and Electro-Optics Europe (CLEO/Europe 2003)
- conference location
- Munich, Germany
- conference dates
- 2003-06-22 - 2003-06-27
- ISBN
- 0-7803-7734-6
- DOI
- 10.1109/CLEOE.2003.1313534
- language
- English
- LU publication?
- yes
- id
- da65d0e9-57f4-403d-9040-def4019fbd89 (old id 612266)
- date added to LUP
- 2016-04-04 11:23:11
- date last changed
- 2018-11-21 21:04:30
@inproceedings{da65d0e9-57f4-403d-9040-def4019fbd89, abstract = {{Field measurements of mercury emissions has been performed by using a mobile lidar system. In this system an Nd:YAG-pumped OPO (Optical Parametric Oscillator) laser system is employed to generate a narrow band (better than 0.2 cm<sup>-1</sup>) UV beam at the mercury resonance absorption line at 253.65 nm. An inter-comparison of the lidar system and two different point monitoring systems has been performed showing excellent agreement between the instruments}}, author = {{Sjöholm, Mikael and Weibring, Petter and Edner, Hans and Svanberg, Sune}}, booktitle = {{2003 Conference on Lasers and Electro-Optics Europe (CLEO/Europe 2003) (IEEE Cat. No.03TH8666)}}, isbn = {{0-7803-7734-6}}, keywords = {{UV beam generation; OPO; atomic mercury monitoring; optical parametric oscillator; field measurements; mercury emissions; mobile lidar system; pumping; Nd:YAG; 253.65 nm; Hg; YAG:Nd; YAl5O12:Nd}}, language = {{eng}}, pages = {{471--471}}, publisher = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}}, title = {{Optical parametric oscillator based lidar system applied to atomic mercury monitoring}}, url = {{http://dx.doi.org/10.1109/CLEOE.2003.1313534}}, doi = {{10.1109/CLEOE.2003.1313534}}, year = {{2003}}, }