Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size

Dencker, Magnus LU ; Arvidsson, Daniel ; Karlsson, Magnus K. LU ; Wollmer, Per LU ; Andersen, Lars B. and Thorsson, Ola LU (2018) In European Journal of Pediatrics 177(3). p.461-467
Abstract

Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8–11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and... (More)

Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8–11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. Conclusion: More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3.(Table presented.)

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Body fat, Children, DXA, Galectin-3
in
European Journal of Pediatrics
volume
177
issue
3
pages
461 - 467
publisher
Springer
external identifiers
  • pmid:29327139
  • scopus:85040344167
ISSN
0340-6199
DOI
10.1007/s00431-017-3079-5
language
English
LU publication?
yes
id
cdf0108f-fc7e-43e1-800c-5f1c3fad6817
date added to LUP
2018-02-23 18:28:52
date last changed
2024-03-18 05:36:24
@article{cdf0108f-fc7e-43e1-800c-5f1c3fad6817,
  abstract     = {{<p>Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8–11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. Conclusion: More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3.(Table presented.)</p>}},
  author       = {{Dencker, Magnus and Arvidsson, Daniel and Karlsson, Magnus K. and Wollmer, Per and Andersen, Lars B. and Thorsson, Ola}},
  issn         = {{0340-6199}},
  keywords     = {{Body fat; Children; DXA; Galectin-3}},
  language     = {{eng}},
  month        = {{01}},
  number       = {{3}},
  pages        = {{461--467}},
  publisher    = {{Springer}},
  series       = {{European Journal of Pediatrics}},
  title        = {{Galectin-3 levels relate in children to total body fat, abdominal fat, body fat distribution, and cardiac size}},
  url          = {{http://dx.doi.org/10.1007/s00431-017-3079-5}},
  doi          = {{10.1007/s00431-017-3079-5}},
  volume       = {{177}},
  year         = {{2018}},
}