Sorensen, S.L. LU ; Olsson, B. J. ; Widlund, O ; Huldt, S. LU ; Johansson, Sveneric LU ; Källne, E ; Nilsson, A.E. LU orcid ; Hutton, R. LU ; Litzén, U. LU and Svensson, A (1990) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 297(1-2). p.296-300
Abstract
A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 1010 at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the... (More)
A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 1010 at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the requirement of fixed slits and fixed exit beam. (Less)
Abstract (Swedish)
A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 1010 at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the... (More)
A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 1010 at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the requirement of fixed slits and fixed exit beam. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
297
issue
1-2
pages
5 pages
publisher
Elsevier
external identifiers
  • scopus:0242295495
ISSN
0168-9002
DOI
10.1016/0168-9002(90)91377-N
language
English
LU publication?
yes
id
0193b114-bbf5-400a-949f-725ea7254590
alternative location
https://www.sciencedirect.com/science/article/pii/016890029091377N
date added to LUP
2023-09-15 15:43:56
date last changed
2024-01-04 04:48:50
@article{0193b114-bbf5-400a-949f-725ea7254590,
  abstract     = {{A 1-m normal-incidence monochromator has been designed and installed on a bending-magnet beam line at the MAX storage ring in Lund. The optical properties of the beam line have been investigated via ray-tracing studies and with flux measurements of the beam line-monochromator combination. A resolution of 0.9 Å at 919.8 Å was measured in first-order diffraction with an argon hollow-cathode lamp for slit openings of 100 μm. A photon flux of 2.0 × 10<sup>10</sup> at 550 Å with 250 μm slits was measured with a calibrated GaAs photodiode through a 1.5-mm diameter aperture in an aluminum mask on the photodiode. The new instrument has a microcomputer controlled mechanism which optimizes focussing requirements for a scanning monochromator with the requirement of fixed slits and fixed exit beam.}},
  author       = {{Sorensen, S.L. and Olsson, B. J. and Widlund, O and Huldt, S. and Johansson, Sveneric and Källne, E and Nilsson, A.E. and Hutton, R. and Litzén, U. and Svensson, A}},
  issn         = {{0168-9002}},
  language     = {{eng}},
  number       = {{1-2}},
  pages        = {{296--300}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{A normal-incidence beam line at the MAX storage ring}},
  url          = {{http://dx.doi.org/10.1016/0168-9002(90)91377-N}},
  doi          = {{10.1016/0168-9002(90)91377-N}},
  volume       = {{297}},
  year         = {{1990}},
}