Current status of dosimetry at the boron neutron capture therapy facility at Studsvik, Sweden

Munck af Rosenschöld, Per LU orcid ; Giusti, V ; Capala, J ; Ceberg, Crister LU orcid ; Skold, K ; Andreoiu, Corina LU ; H-Stenstam, B ; Salford, Leif LU and Persson, Bertil R LU orcid (2002) 10th International Congress on Neutron Capture Therapy p.437-441
Abstract
The beam was successfully characterized in air and in phantom using various radiation dosimeter:,. The determination of the thermal neutron and photon components of the mixed beam in phantom can be determined with acceptable uncertainties, while the uncertainty of the high-energy neutron component is considerable but of limited clinical significance. The beam intensity is sufficiently high for reasonably short treatment times. A novel approach to in-vivo dosimetry and quality assurance of treatment time in terms of monitor units was introduced in order to comply with national regulations regarding radiation therapy.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Research and Development in Neutron Capture Therapy
pages
437 - 441
publisher
Medimond
conference name
10th International Congress on Neutron Capture Therapy
conference location
Essen, Germany
conference dates
2002-09-08 - 2002-09-13
external identifiers
  • wos:000178661500076
ISBN
978-88-3232-909-4
language
English
LU publication?
yes
id
93c12151-9690-460e-b737-49747ae9f58d (old id 1407280)
date added to LUP
2016-04-04 12:25:27
date last changed
2023-07-20 08:31:41
@inproceedings{93c12151-9690-460e-b737-49747ae9f58d,
  abstract     = {{The beam was successfully characterized in air and in phantom using various radiation dosimeter:,. The determination of the thermal neutron and photon components of the mixed beam in phantom can be determined with acceptable uncertainties, while the uncertainty of the high-energy neutron component is considerable but of limited clinical significance. The beam intensity is sufficiently high for reasonably short treatment times. A novel approach to in-vivo dosimetry and quality assurance of treatment time in terms of monitor units was introduced in order to comply with national regulations regarding radiation therapy.}},
  author       = {{Munck af Rosenschöld, Per and Giusti, V and Capala, J and Ceberg, Crister and Skold, K and Andreoiu, Corina and H-Stenstam, B and Salford, Leif and Persson, Bertil R}},
  booktitle    = {{Research and Development in Neutron Capture Therapy}},
  isbn         = {{978-88-3232-909-4}},
  language     = {{eng}},
  pages        = {{437--441}},
  publisher    = {{Medimond}},
  title        = {{Current status of dosimetry at the boron neutron capture therapy facility at Studsvik, Sweden}},
  year         = {{2002}},
}