Reliable LIF/Mie droplet sizing in sprays using structured laser illumination planar imaging
(2014) In Optics Express 22(4). p.4480-4492- Abstract
- In this article, Structured Laser Illumination Planar Imaging (SLIPI) is used in combination with the LIF/Mie ratio technique for extracting a reliable two-dimensional mapping of the droplets Sauter Mean Diameter (SMD). We show that even for the case of a fairly dilute spray, where single scattering events are in majority, the conventional LIF/Mie technique still remains largely affected by errors introduced by multiple light scattering. To remove this unwanted light intensity on both the LIF and Mie images SLIPI is used prior to apply the image ratio. For the first time, the SLIPI LIF/Mie results are calibrated and compared with measurement data from Phase Doppler Interferometry (PDI).
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4355057
- author
- Mishra, Yogeshwar LU ; Kristensson, Elias LU and Berrocal, Edouard LU
- organization
- publishing date
- 2014
- type
- Contribution to specialist publication or newspaper
- publication status
- published
- subject
- keywords
- Fluorescence, Multiple scattering, particles, Scattering, laser-induced, Imaging through turbid media
- categories
- Higher Education
- in
- Optics Express
- volume
- 22
- issue
- 4
- pages
- 4480 - 4492
- publisher
- Optical Society of America
- external identifiers
-
- wos:000332520000079
- scopus:84894754269
- ISSN
- 1094-4087
- DOI
- 10.1364/OE.22.004480
- language
- English
- LU publication?
- yes
- id
- 7c7f79ca-d3da-4886-b353-99fdea378b09 (old id 4355057)
- alternative location
- http://www.opticsexpress.org/abstract.cfm?URI=oe-22-4-4480
- date added to LUP
- 2016-04-01 14:02:36
- date last changed
- 2022-04-22 01:06:12
@misc{7c7f79ca-d3da-4886-b353-99fdea378b09, abstract = {{In this article, Structured Laser Illumination Planar Imaging (SLIPI) is used in combination with the LIF/Mie ratio technique for extracting a reliable two-dimensional mapping of the droplets Sauter Mean Diameter (SMD). We show that even for the case of a fairly dilute spray, where single scattering events are in majority, the conventional LIF/Mie technique still remains largely affected by errors introduced by multiple light scattering. To remove this unwanted light intensity on both the LIF and Mie images SLIPI is used prior to apply the image ratio. For the first time, the SLIPI LIF/Mie results are calibrated and compared with measurement data from Phase Doppler Interferometry (PDI).}}, author = {{Mishra, Yogeshwar and Kristensson, Elias and Berrocal, Edouard}}, issn = {{1094-4087}}, keywords = {{Fluorescence; Multiple scattering; particles; Scattering; laser-induced; Imaging through turbid media}}, language = {{eng}}, number = {{4}}, pages = {{4480--4492}}, publisher = {{Optical Society of America}}, series = {{Optics Express}}, title = {{Reliable LIF/Mie droplet sizing in sprays using structured laser illumination planar imaging}}, url = {{https://lup.lub.lu.se/search/files/85589580/oe_22_4_4480.pdf}}, doi = {{10.1364/OE.22.004480}}, volume = {{22}}, year = {{2014}}, }