Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Baseline QRS Area and Reduction in QRS Area Are Associated with Lower Mortality and Risk of Heart Failure Hospitalization after Cardiac Resynchronization Therapy

Marinko, Sofia LU ; Platonov, Pyotr G. LU ; Carlson, Jonas LU orcid and Borgquist, Rasmus LU orcid (2022) In Cardiology (Switzerland) 147(3). p.298-306
Abstract

Introduction: Cardiac resynchronization therapy (CRT) is an established treatment for heart failure in selected patients. However, current guideline indications do not accurately predict individual prognosis with CRT, and up to 30% are nonresponders. Previous studies have shown that QRS area reduction following CRT is associated with improved survival. This study evaluates the incremental value of using QRS area derived from digital electrocardiogram (ECG) recordings, preoperatively and during CRT pacing. Methods: Medical records of 445 patients receiving CRT implants at a large-volume tertiary care center in Sweden were retrospectively evaluated. Digital ECG before and after CRT implantation were collected, and ECG parameters were... (More)

Introduction: Cardiac resynchronization therapy (CRT) is an established treatment for heart failure in selected patients. However, current guideline indications do not accurately predict individual prognosis with CRT, and up to 30% are nonresponders. Previous studies have shown that QRS area reduction following CRT is associated with improved survival. This study evaluates the incremental value of using QRS area derived from digital electrocardiogram (ECG) recordings, preoperatively and during CRT pacing. Methods: Medical records of 445 patients receiving CRT implants at a large-volume tertiary care center in Sweden were retrospectively evaluated. Digital ECG before and after CRT implantation were collected, and ECG parameters were analyzed in relation to a primary composite endpoint of heart failure hospitalization or death from any cause. Results: 147 patients (33%) reached the primary endpoint (93 deaths and 103 heart failure hospitalizations) over a median follow-up time of 2.7 years. A larger preimplant QRS area (HR, 0.89; [0.85-0.93]; p = <0.0001; adjusted HR, 0.93; [0.88-0.98]; p = 0.011) and a larger QRS area reduction (HR, 0.92; [0.88-0.96]; p = <0.0001; adjusted HR, 0.95; [0.90-0.99]; p = 0.042) postimplant correlated with a reduced risk of reaching the primary endpoint. This association was seen in patients with native left bundle branch block morphology, nonspecific intraventricular conduction delay, or paced ECG morphology but not in patients with right bundle branch block. Conclusion: Larger preimplant QRS area and QRS area reduction were associated with better clinical outcome following CRT in this retrospective material. This knowledge could help optimize patient selection and postoperative management.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Cardiac resynchronization therapy, Heart failure, Patient selection, Prognosis
in
Cardiology (Switzerland)
volume
147
issue
3
pages
9 pages
publisher
Karger
external identifiers
  • scopus:85134083141
  • pmid:35073550
ISSN
0008-6312
DOI
10.1159/000522151
language
English
LU publication?
yes
additional info
Funding Information: ALF grant within the Swedish Health Care System and Swedish Heart-Lung Foundation grant.
id
b8e80402-17c3-4c1c-a16c-473a727f95c4
date added to LUP
2022-09-07 14:03:44
date last changed
2024-06-13 19:07:36
@article{b8e80402-17c3-4c1c-a16c-473a727f95c4,
  abstract     = {{<p>Introduction: Cardiac resynchronization therapy (CRT) is an established treatment for heart failure in selected patients. However, current guideline indications do not accurately predict individual prognosis with CRT, and up to 30% are nonresponders. Previous studies have shown that QRS area reduction following CRT is associated with improved survival. This study evaluates the incremental value of using QRS area derived from digital electrocardiogram (ECG) recordings, preoperatively and during CRT pacing. Methods: Medical records of 445 patients receiving CRT implants at a large-volume tertiary care center in Sweden were retrospectively evaluated. Digital ECG before and after CRT implantation were collected, and ECG parameters were analyzed in relation to a primary composite endpoint of heart failure hospitalization or death from any cause. Results: 147 patients (33%) reached the primary endpoint (93 deaths and 103 heart failure hospitalizations) over a median follow-up time of 2.7 years. A larger preimplant QRS area (HR, 0.89; [0.85-0.93]; p = &lt;0.0001; adjusted HR, 0.93; [0.88-0.98]; p = 0.011) and a larger QRS area reduction (HR, 0.92; [0.88-0.96]; p = &lt;0.0001; adjusted HR, 0.95; [0.90-0.99]; p = 0.042) postimplant correlated with a reduced risk of reaching the primary endpoint. This association was seen in patients with native left bundle branch block morphology, nonspecific intraventricular conduction delay, or paced ECG morphology but not in patients with right bundle branch block. Conclusion: Larger preimplant QRS area and QRS area reduction were associated with better clinical outcome following CRT in this retrospective material. This knowledge could help optimize patient selection and postoperative management. </p>}},
  author       = {{Marinko, Sofia and Platonov, Pyotr G. and Carlson, Jonas and Borgquist, Rasmus}},
  issn         = {{0008-6312}},
  keywords     = {{Cardiac resynchronization therapy; Heart failure; Patient selection; Prognosis}},
  language     = {{eng}},
  month        = {{07}},
  number       = {{3}},
  pages        = {{298--306}},
  publisher    = {{Karger}},
  series       = {{Cardiology (Switzerland)}},
  title        = {{Baseline QRS Area and Reduction in QRS Area Are Associated with Lower Mortality and Risk of Heart Failure Hospitalization after Cardiac Resynchronization Therapy}},
  url          = {{http://dx.doi.org/10.1159/000522151}},
  doi          = {{10.1159/000522151}},
  volume       = {{147}},
  year         = {{2022}},
}