Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source
(2016) In Scientific Data 3.- Abstract
Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described... (More)
Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
(Less)
- author
- publishing date
- 2016-08-01
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- coherent diffraction imaging, rice dwarf virus, single-particle imaging, XFEL, free electron laser, X-ray free-electron laser (XFEL), virus
- in
- Scientific Data
- volume
- 3
- article number
- 160064
- publisher
- Nature Publishing Group
- external identifiers
-
- scopus:84982746851
- pmid:27478984
- ISSN
- 2052-4463
- DOI
- 10.1038/sdata.2016.64
- language
- English
- LU publication?
- no
- id
- d4ea45cc-e451-4bb3-943d-92e51afaa7e9
- date added to LUP
- 2025-04-21 20:58:03
- date last changed
- 2025-04-30 03:34:10
@article{d4ea45cc-e451-4bb3-943d-92e51afaa7e9, abstract = {{<p>Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.</p>}}, author = {{Munke, Anna and Andreasson, Jakob and Aquila, Andrew and Awel, Salah and Ayyer, Kartik and Barty, Anton and Bean, Richard J. and Berntsen, Peter and Bielecki, Johan and Boutet, Sébastien and Bucher, Maximilian and Chapman, Henry N. and Daurer, Benedikt J. and Demirci, Hasan and Elser, Veit and Fromme, Petra and Hajdu, Janos and Hantke, Max F. and Higashiura, Akifumi and Hogue, Brenda G. and Hosseinizadeh, Ahmad and Kim, Yoonhee and Kirian, Richard A. and Reddy, Hemanth K.N. and Lan, Ti Yen and Larsson, Daniel S.D. and Liu, Haiguang and Loh, N. Duane and Maia, Filipe R.N.C. and Mancuso, Adrian P. and Mühlig, Kerstin and Nakagawa, Atsushi and Nam, Daewoong and Nelson, Garrett and Nettelblad, Carl and Okamoto, Kenta and Ourmazd, Abbas and Rose, Max and van der Schot, Gijs and Schwander, Peter and Seibert, M. Marvin and Sellberg, Jonas A. and Sierra, Raymond G. and Song, Changyong and Svenda, Martin and Timneanu, Nicusor and Vartanyants, Ivan A. and Westphal, Daniel and Wiedorn, Max O. and Williams, Garth J. and Xavier, Paulraj Lourdu and Yoon, Chun Hong and Zook, James}}, issn = {{2052-4463}}, keywords = {{coherent diffraction imaging; rice dwarf virus; single-particle imaging; XFEL; free electron laser; X-ray free-electron laser (XFEL); virus}}, language = {{eng}}, month = {{08}}, publisher = {{Nature Publishing Group}}, series = {{Scientific Data}}, title = {{Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source}}, url = {{http://dx.doi.org/10.1038/sdata.2016.64}}, doi = {{10.1038/sdata.2016.64}}, volume = {{3}}, year = {{2016}}, }