Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

The upgraded photon tagging facility at the MAX IV Laboratory

Adler, Jan-Olof LU ; Boland, Mark LU ; Brudvik, Jason LU ; Fissum, Kevin LU orcid ; Hansen, Kurt LU ; Isaksson, Lennart LU ; Lilja, Per LU ; Lindgren, Lars-Johan LU ; Lundin, Magnus LU and Nilsson, Björn LU , et al. (2013) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 715. p.1-10
Abstract
A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4 x 10(6) photons s(-1) MeV (-1). Different diagnostic tools are described as well as the experimental program.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Tagging systems, Beam diagnostics, High-energy photon beam, Photonuclear, reactions, Photon scattering
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
715
pages
1 - 10
publisher
Elsevier
external identifiers
  • wos:000319252300001
  • scopus:84876167766
ISSN
0167-5087
DOI
10.1016/j.nima.2013.02.040
project
Elastic and Virtual Compton Scattering and Nucleon Polarizabilities
Development of Radiation Detectors and Radiation-Detection Techniques
language
English
LU publication?
yes
id
bebcc304-5c6d-4f0b-83d6-001d6f566573 (old id 3930538)
date added to LUP
2016-04-01 13:46:02
date last changed
2022-03-29 17:22:10
@article{bebcc304-5c6d-4f0b-83d6-001d6f566573,
  abstract     = {{A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4 x 10(6) photons s(-1) MeV (-1). Different diagnostic tools are described as well as the experimental program.}},
  author       = {{Adler, Jan-Olof and Boland, Mark and Brudvik, Jason and Fissum, Kevin and Hansen, Kurt and Isaksson, Lennart and Lilja, Per and Lindgren, Lars-Johan and Lundin, Magnus and Nilsson, Björn and Pugachov, Dmytro and Sandell, Anders and Schröder, Bent and Avdeichikov, Vladimir and Golubev, Pavel and Jakobsson, Bo and Annand, J. R. M. and Livingston, K. and Igarashi, R. and Myers, L. and Nathan, A. and Briscoe, W. J. and Feldman, G. and Kovash, M. and Branford, D. and Foehl, K. and Grabmayr, P. and Takau, V. and O'Rielly, G. and Burdeynyi, D. and Ganenko, V. and Morochovskyi, V. and Vashchenko, G.}},
  issn         = {{0167-5087}},
  keywords     = {{Tagging systems; Beam diagnostics; High-energy photon beam; Photonuclear; reactions; Photon scattering}},
  language     = {{eng}},
  pages        = {{1--10}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{The upgraded photon tagging facility at the MAX IV Laboratory}},
  url          = {{http://dx.doi.org/10.1016/j.nima.2013.02.040}},
  doi          = {{10.1016/j.nima.2013.02.040}},
  volume       = {{715}},
  year         = {{2013}},
}