Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

First mirror stability at the MAX IV soft x-ray beamlines

Pickworth, L. A. LU ; Sankari, R. ; Sondhauss, P. LU ; Lebugle, M. LU ; Tokushima, T. LU orcid ; Agåker, M. LU ; Preobrajenski, A. LU ; Polley, C. LU ; Leandersson, M. LU and Thiagarajan, B. LU , et al. (2025) 15th International Conference on Synchrotron Radiation Instrumentation, SRI 2024 In Journal of Physics: Conference Series 3010(1).
Abstract

Horizontal drift of the beam on the MAX IV soft x-ray beamlines was observed with a 1-2 hour settling time and strong dependence on the undulator power setting. A water cooled, suspended electrode was designed and is shown to reduce the horizontal beam drift on three MAX IV soft x-ray beamlines to acceptable operational levels.

Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Physics: Conference Series
volume
3010
issue
1
article number
012074
publisher
IOP Publishing
conference name
15th International Conference on Synchrotron Radiation Instrumentation, SRI 2024
conference location
Hamburg, Germany
conference dates
2024-08-26 - 2024-08-30
external identifiers
  • scopus:105007995320
ISSN
1742-6588
DOI
10.1088/1742-6596/3010/1/012074
language
English
LU publication?
yes
additional info
Publisher Copyright: © Published under licence by IOP Publishing Ltd.
id
9e71a76d-da20-4842-b12a-f4c65ba21332
date added to LUP
2026-01-13 14:40:20
date last changed
2026-01-13 14:41:00
@article{9e71a76d-da20-4842-b12a-f4c65ba21332,
  abstract     = {{<p>Horizontal drift of the beam on the MAX IV soft x-ray beamlines was observed with a 1-2 hour settling time and strong dependence on the undulator power setting. A water cooled, suspended electrode was designed and is shown to reduce the horizontal beam drift on three MAX IV soft x-ray beamlines to acceptable operational levels.</p>}},
  author       = {{Pickworth, L. A. and Sankari, R. and Sondhauss, P. and Lebugle, M. and Tokushima, T. and Agåker, M. and Preobrajenski, A. and Polley, C. and Leandersson, M. and Thiagarajan, B. and Chernenko, K. and Thånell, K. and Mårsell, E. and Schwenke, J. and Beinik, I. and Shavorskiy, A. and Yaroslavtsev, A. and Adell, J. and Ryll, H. and Henninger, H. and Cerenius, Y.}},
  issn         = {{1742-6588}},
  language     = {{eng}},
  number       = {{1}},
  publisher    = {{IOP Publishing}},
  series       = {{Journal of Physics: Conference Series}},
  title        = {{First mirror stability at the MAX IV soft x-ray beamlines}},
  url          = {{http://dx.doi.org/10.1088/1742-6596/3010/1/012074}},
  doi          = {{10.1088/1742-6596/3010/1/012074}},
  volume       = {{3010}},
  year         = {{2025}},
}