Nuclear Microprobe-lup-obsolete
1 – 47 of 47
- show: 250
- |
- sort: year (new to old)
Close
Embed this list
<iframe src=" "
width=" "
height=" "
allowtransparency="true"
frameborder="0">
</iframe>
- 2014
-
Mark
Fabrication, Simulation and Performance of Ultra-Thin Silicon Detectors-Development of a Detection System for Living Cell Irradiation
2014)(
- Thesis › Doctoral thesis (monograph)
- 2013
-
Mark
Fabrication and Characterisations of New Ultra-thin Silicon Detectors as Pre-Cell Hit Detectors for a Cell Irradiation Facility at LIBAF
2013)(
- Thesis › Licentiate thesis
-
Mark
Development of techniques for light isotope analysis at LIBAF
2013)(
- Thesis › Doctoral thesis (monograph)
- 2010
-
Mark
Single-Proton Irradiation of Living Cells - Development of New Tools for Low-Dose Radiation Research
2010)(
- Thesis › Doctoral thesis (compilation)
- 2008
-
Mark
New tools for probing biological extremes of ionizing radiation
2008)(
- Thesis › Doctoral thesis (compilation)
- 2007
-
Mark
The new cell irradiation facility at the Lund nuclear probe
2007) 10th International Conference on Nuclear Microprobe Technology and Applications and 2nd International Workshop on Proton Beam Writing In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 260(1). p.91-96(
- Contribution to journal › Article
-
Mark
Symbiotic fungi that are essential for plant nutrient uptake investigated with NMP
2007) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 260(1). p.149-152(
- Contribution to journal › Article
-
Mark
A SU-8 dish for cell irradiation
2007) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 263(2). p.523-528(
- Contribution to journal › Article
-
Mark
A Fast Analysis Technique to Evaluate Scintillation Response
2007) In IEEE Transactions of Nuclear Science(
- Contribution to journal › Article
-
Mark
The new target chamber at LIPSION: The new translation stage and goniometer and the new irradiation platform for single cell experiments
(
- Contribution to journal › Article
- 2006
-
Mark
Exposure parameters for MeV proton beam writing on SU-8
(
- Contribution to journal › Article
-
Mark
Particle probes and skin physiology
2006)(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Status of the new Single Ion Hit Facility for Irradiation of Single Living Cells at LIPSION
(
- Contribution to journal › Article
-
Mark
Development of the Lund Single Ion Hit Facility at the new sub micrometer beamline
(
- Contribution to journal › Article
-
Mark
Performance of an alpha-IPEM
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Titanium incorporation and Ti-VI(3+)-Ti-IV(4+) charge transfer in synthetic diopside
(
- Contribution to journal › Article
-
Mark
On-line measurement of proton beam current in pA range
2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 249. p.760-763(
- Contribution to journal › Article
-
Mark
Development of a microtomography system at the Lund sub-micron beamline
2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 249(1-2). p.756-759(
- Contribution to journal › Article
-
Mark
Fabrication of phosphor micro-grids using proton beam lithography
2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 242(1-2). p.253-256(
- Contribution to journal › Article
-
Mark
Evaluation of a pre-cell hit detector for the future single ion hit facility in Lund
2006) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 249(1-2). p.924-927(
- Contribution to journal › Article
- 2005
-
Mark
The elemental content in the mycelium of the ectomycorrhizal fungus Piloderma sp during the colonization of hardened wood ash
(
- Contribution to journal › Article
-
Mark
Concluding remarks of the Fifth International Symposium on Bio-PIXE
(
- Contribution to journal › Article
-
Mark
Accelerator-based Ion Beam Analysis
2005)(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
The Lund Nuclear Microprobe sub-micron set-up. Part III: Sample stage, optical imaging and detector configuration in the experimental chamber
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.14-20(
- Contribution to journal › Article
-
Mark
Hydrogen depth profiling by p-p scattering in nominally anhydrous minerals
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.524-529(
- Contribution to journal › Article
-
Mark
The Lund Nuclear Microprobe sub-micron set-up. Part II: Beam line, focusing system and scanning
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.7-13(
- Contribution to journal › Article
-
Mark
The Lund Nuclear Microprobe sub-micron set-up. Part I: Ion optics calculation
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.1-6(
- Contribution to journal › Article
-
Mark
Skin morphology and layer identification using different STIM geometries
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.292-299(
- Contribution to journal › Article
-
Mark
Optimization of PIXE-sensitivity for detection of Ti in thin human skin sections
2005) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 231(1-4). p.274-279(
- Contribution to journal › Article
-
Mark
Temporal changes in the elemental composition of Rhizopogon rhizomorphs during colonization of patches with fresh organic matter or acid-washed sand
(
- Contribution to journal › Article
- 2004
-
Mark
Development of a system for determination of the C-13/C-12 isotopic ratio with high spatial resolution
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.561-566(
- Contribution to journal › Article
-
Mark
Nuclear microprobe analysis of the selective boron uptake obtained with BPA in brain tumour tissue
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.67-71(
- Contribution to journal › Article
-
Mark
The beam blanking system for microlithography at Lund Nuclear microprobe
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.485-489(
- Contribution to journal › Article
-
Mark
Hydrogen analysis by p-p scattering in geological material
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.550-554(
- Contribution to journal › Article
-
Mark
Characterization of a new large area HPGe X-ray detector for low beam current application
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.494-498(
- Contribution to journal › Article
-
Mark
An off-axis STIM procedure for precise mass determination and imaging
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.988-993(
- Contribution to journal › Article
-
Mark
Evaluation of low-energy tailing parameters of a HPGe X-ray detector to be used in GUPIX software library for PIXE analysis
2004) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 219-20. p.110-114(
- Contribution to journal › Article
- 2003
-
Mark
Elemental composition of ectomycorrhizal mycelia identified by PCR-RFLP analysis and grown in contact with apatite or wood ash in forest soil
(
- Contribution to journal › Article
-
Mark
New Insights into Fish Ecology via Nuclear Microscopy of Otoliths
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2002
-
Mark
Dinophysis blooms in the deep euphotic zone of the Baltic Sea: do they grow in the dark?
(
- Contribution to journal › Article
-
Mark
Particle Accelerators for nuclear Microprobes
2002) North Easter Accelerator Personnel Conference(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Calibration of a new chamber using GUPIX software package for PIXE analysis
2002) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 189(1-4). p.131-137(
- Contribution to journal › Article
-
Mark
PIXE analysis to estimate the elemental composition of ectomycorrhizal rhizomorphs grown in contact with different minerals in forest soil
(
- Contribution to journal › Article
-
Mark
The penetration depth and lateral distribution of pigment related to the pigment grain size and the calendering of paper
2002) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 189. p.308-314(
- Contribution to journal › Article
-
Mark
Particle-Induced X-ray Emission Analysis
2002)(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Conference summary
(
- Contribution to journal › Article
- 1999
-
Mark
Quality indicators for woodwind reed material
1999) In Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms 150(1-4). p.673-678(
- Contribution to journal › Article