Amitava Halder
1 – 50 of 50
- show: 250
- |
- sort: year (new to old)
Close
Embed this list
<iframe src=" "
width=" "
height=" "
allowtransparency="true"
frameborder="0">
</iframe>
- 2023
-
Mark
Gait Biomechanics While Walking Down an Incline After Exhaustion
(
- Contribution to journal › Article
-
Mark
Validating an advanced smartphone application for thermal advising in cold environments
(
- Contribution to journal › Article
- 2021
-
Mark
Climapp—integrating personal factors with weather forecasts for individualised warning and guidance on thermal stress
(
- Contribution to journal › Article
-
Mark
Effects of leg fatigue due to exhaustive stair climbing on gait biomechanics while walking up a 10˚ incline – implications for evacuation and work safety
2021) In Fire Safety Journal(
- Contribution to journal › Article
-
Mark
Update of clothing database for existing and new Western clothing ensembles, including effects of posture, body and air movement : Report on manikin measurements for ASHRAE 1760-TRP.
2021)(
- Book/Report › Report
- 2020
-
Mark
The impact of carrying load on physical performance during ascending evacuation movement
2020) In Fire and Materials(
- Contribution to journal › Article
-
Mark
The Fight on the Flights : Emergency evacuations – human physiological performance, leg muscle activity and gait biomechanics during exhaustive stair and slope ascent
2020) In Doctoral Dissertation Series 2020(
- Thesis › Doctoral thesis (compilation)
-
Mark
Physiological Capacity During Simulated Stair Climbing Evacuation at Maximum Speed Until Exhaustion
2020) In Fire Technology(
- Contribution to journal › Article
- 2019
-
Mark
Predicted Heat Strain (PHS) model and the sweat loss in an extremely hot climate
2019) International Conference on Environmental Ergonomics 2019(
- Contribution to conference › Abstract
-
Mark
Comparison of different clothing area factor (fcl) calculations based on picture analysis in Adobe Photoshop : To calculate the intrinsic insulation (Icl)
2019) International Conference on Environmental Ergonomics 2019(
- Contribution to conference › Abstract
-
Mark
Required clothing insulation (IREQ - ISO 11079) and difference of thermal sensations between genders
2019) p.171-171(
- Contribution to conference › Abstract
-
Mark
Does a building renovation improve the indoor thermal comfort? : A thermal environment evaluation before and after renovation
2019) The International Societies of Exposure Science (ISES) and Indoor Air Quality and Climate (ISIAQ), 2019(
- Contribution to conference › Abstract
- 2018
-
Mark
Muscle electrical activity changes over time during stair ascending until exhaustion
2018)(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Oxygen uptake and muscle activity limitations during stepping on a stair machine at three different climbing speeds
(
- Contribution to journal › Article
-
Mark
Balance in standing on inclined surfaces with different friction
(
- Contribution to journal › Article
- 2017
-
Mark
Ascending stair evacuation: walking speed as a function of height
(
- Contribution to journal › Article
-
Mark
Evaluation of physical work capacity and leg muscle fatigue during exhaustive stair ascending evacuation
2017)(
- Thesis › Licentiate thesis
-
Mark
Limitations of oxygen uptake and leg muscle activity during ascending evacuation in stairways
(
- Contribution to journal › Article
-
Mark
Dynamic work induced muscle activity rate change (MARC) and fatigue evaluation in muscle activity interpretation squares (MAIS)
(
- Contribution to conference › Abstract
-
Mark
Validation of body-mapping sports shirts designs on thermal physiological responses and comfort in warm and humid environment
2017) p.181-181(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Thermophysiological responses of exercising in body mapping T-shirts in a warm and humid environment: subject test and predicted heat strain
(
- Contribution to conference › Abstract
- 2016
-
Mark
An experiment on ascending evacuation on a long, stationary escalator
2016) Interflam’16, 14th International Conference and Exhibition on Fire Science and Engineering, London, UK, 4- 6th July 2016(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Evaluation of BARRIER® EasyWarm on healthy volunteers in three different climates
(
- Contribution to conference › Abstract
-
Mark
A model to estimate vertical speed of ascending evacuation from maximal work capacity data
(
- Contribution to journal › Article
-
Mark
Whole body heat balance and local insulation required to prevent extremity cooling in extremely cold environments
2016) p.165-165(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Estimation of vertical displacement during ascending evacuation
2016) p.145-150(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2015
-
Mark
Validation of standard ASTM F2732 and comparison with ISO 11079 with respect to comfort temperature ratings for cold protective clothing
(
- Contribution to journal › Article
-
Mark
The “AVA - organ”
2015) 16th International Conference on Environmental Ergonomics, 2015 In Environmental Ergonomics XVI. p.114-114(
- Contribution to journal › Published meeting abstract
-
Mark
Evaluation of BARRIER® EasyWarm on Healthy Volunteers in Three Different Climates and Verification of the Degree of Correlation Between Tests Performed on Healthy Volunteers and in a standardized bench test
2015) In Clinical Investigation Report(
- Book/Report › Report
-
Mark
Response patterns in finger and central body skin temperatures under mild whole body cooling in an elderly and in a young male – a pre-study
2015) 16th International Conference on Environmental Ergonomics, 2015 In Environmental Ergonomics XVI. p.48-48(
- Contribution to journal › Published meeting abstract
-
Mark
Ascending Stair Evacuation – effects of fatigue, walking speed & human behaviour
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
The colder is warmer? A pre-study for wear trials of a reference clothing ensemble for EN 342 and EN 14058 for thermal manikin calibration
2015) 16th International Conference on Environmental Ergonomics, 2015 In Environmental Ergonomics XVI. p.181-181(
- Contribution to journal › Published meeting abstract
-
Mark
Ascending evacuation - Walking speed in stairs as a function of height
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Assessment of workload in heat: an approach with accelerometers
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Cold induced vasodilation during continuous exercise in the extreme cold air (– 30.6 °C)
2015) International Conference on Environmental Ergonomics (ICEE) In Extreme Physiology & Medicine 20154 (Suppl 1) :A58. p.75-75(
- Contribution to journal › Published meeting abstract
-
Mark
Age‐related circulatory responses to whole body cooling: observations by heart rate variability
(
- Contribution to journal › Article
-
Mark
What is the role of traditional fermented foods to prevent heat stress at work?
(
- Contribution to journal › Published meeting abstract
-
Mark
Effects of cooling on muscle function and duration of stance phase during gait
2015) 16th International Conference on Environmental Ergonomics (ICEE).(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Energy costs and leg muscle activities in ascending stairs
2015)(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Energy costs and leg muscle activities in ascending stairs
2015) 20th annual Congress of the European College of Sport Science(
- Contribution to conference › Abstract
-
Mark
Ascending evacuation in long stairways: Physical exertion, walking speed and behaviour
2015) In TVBB-3192(
- Book/Report › Report
-
Mark
Effects of cooling on muscle function and duration of stance phase during gait
2015) 16th International Conference on Environmental Ergonomics, 2015(
- Contribution to conference › Abstract
- 2014
-
Mark
Effects of Cooling on Ankle Muscle Strength, Electromyography, and Gait Ground Reaction Forces
(
- Contribution to journal › Article
-
Mark
Using a walkway with adjustable inclination to measure and assess slip and fall risks
2014) CIB W099 International Health and Safety Conference on Achieving Sustainable Construction Health and Safety p.118-124(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Muscle Cooling and Performance: A Review
(
- Contribution to journal › Scientific review
-
Mark
Age-related circulatory responses to whole body cooling: observations by ballistocardiographic EMFi sensors
2014) Ambience14 & 10I3M, Scientific conference for Smart and functional textiles, Well-Being, Thermal comfort in clothing, Design, Thermal Manikins and Modelling In Proceedings of Ambience, Scientific Conference for Smart Textiles 1.(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2013
-
Mark
Effects of cooling on ankle muscle maximum performances, gait ground reaction forces and electromyography (EMG)
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Halk- och fallolyckor, friktionskrav och balansförmåga
2013)(
- Book/Report › Report
-
Mark
Validation of ASTM standard F2732 and comparison with ISO 11079 with respect to temperature ratings for cold weather protective clothing
(
- Contribution to conference › Abstract
- 2012
-
Mark
Effects of Cooling on Ankle Muscle Maximum Performances, Gait Ground Reaction Forces and Electromyography (EMG)
2012)(
- Thesis › Master's thesis