Michael Ljungberg
1 – 167 of 167
- show: 250
- |
- sort: year (new to old)
Close
Embed this list
<iframe src=" "
width=" "
height=" "
allowtransparency="true"
frameborder="0">
</iframe>
- 2024
-
Mark
Accuracy of patient-specific I-131 dosimetry using hybrid whole-body planar-SPECT/CT I-123 and I-131 imaging
(
- Contribution to journal › Article
-
Mark
3D printed non-uniform anthropomorphic phantoms for quantitative SPECT
(
- Contribution to journal › Article
-
Mark
Feasibility of 177Lu activity quantification using a small portable CZT-based gamma-camera
(
- Contribution to journal › Article
-
Mark
Pareto optimization of SPECT acquisition and reconstruction settings for 177Lu activity quantification
(
- Contribution to journal › Article
- 2023
-
Mark
Assessment of a hand-held CZT-based gamma camera for pre-clinical imaging of 177Lu
2023) 2023 IEEE Nuclear Science Symposium and Medical Imaging Conference(
- Contribution to conference › Poster
-
Mark
Investigation of a CZT-based hand-held gamma-camera for pre-clinical imaging of alpha-emitter 225Ac
2023) Annual Congress of the European Association of Nuclear Medicine In European Journal of Nuclear Medicine and Molecular Imaging 50(Suppl 1). p.129-129(
- Contribution to journal › Published meeting abstract
-
Mark
Monte Carlo investigation of PET [68Ga]Ga-DOTA-TOC activity-administration protocols for consistent image quality
(
- Contribution to journal › Article
-
Mark
99mTc/123I Dual-Radionuclide Correction for Self-Scatter, Down-Scatter, and Tailing Effect for a CZT SPECT With Varying Tracer Distributions
(
- Contribution to journal › Article
-
Mark
Averaging of absorbed doses : How matter matters
(
- Contribution to journal › Article
-
Mark
Machine learning-based prediction of conversion coefficients for I-123 metaiodobenzylguanidine heart-to-mediastinum ratio
(
- Contribution to journal › Article
-
Mark
On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration : a European multi-centre evaluation
(
- Contribution to journal › Article
- 2022
-
Mark
Validation of a computational chain from PET Monte Carlo simulations to reconstructed images
(
- Contribution to journal › Article
-
Mark
Phase II trial demonstrates the efficacy and safety of individualized, dosimetry-based 177Lu-DOTATATE treatment of NET patients
(
- Contribution to journal › Article
-
Mark
A 3D-printed mouse phantom for the evaluation of a hand-held CZT-based gamma camera
2022) 2022 Höstmöte för Cancerfondens Planeringsgrupp för Onkologisk Radionuklidterapi(
- Contribution to conference › Abstract
-
Mark
Basics of Radiation Interactions in Matter
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Single Photon Emission Computed Tomography (SPECT) and SPECT/CT Hybrid Imaging
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Multicentre Studies
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Monte Carlo Simulation of Nuclear Medicine Imaging Systems
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Radiopharmaceuticals and Clinical Applications, Volume III
- Book/Report › Anthology (editor)
-
Mark
Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Instrumentation and Imaging Procedures, Volume I
- Book/Report › Anthology (editor)
-
Mark
Basic Atomic and Nuclear Physics
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Modelling, Dosimetry and Radiation Protection, Volume II
- Book/Report › Anthology (editor)
-
Mark
Preface
2022) 2.(
- Chapter in Book/Report/Conference proceeding › Foreword/Postscript
-
Mark
Monte Carlo modelling of a compact CZT-based gamma camera with application to 177Lu imaging
(
- Contribution to journal › Article
-
Mark
A Statistical DOI Estimation Algorithm for a SiPM-Based Clinical SPECT Insert
(
- Contribution to journal › Article
- 2021
-
Mark
Modelling of energy-dependent spectral resolution for SPECT Monte Carlo simulations using SIMIND
(
- Contribution to journal › Article
-
Mark
A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project
(
- Contribution to journal › Article
-
Mark
Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging
(
- Contribution to journal › Article
-
Mark
Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification : a Monte Carlo study
(
- Contribution to journal › Article
- 2020
-
Mark
Impact of DOI in a Clinical SPECT/MRI System : A Simulation Study
2020) 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2020(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2018
-
Mark
Feasibility of simplifying renal dosimetry in 177Lu peptide receptor radionuclide therapy
(
- Contribution to journal › Article
-
Mark
Monte Carlo-based SPECT reconstruction within the SIMIND framework
(
- Contribution to journal › Article
-
Mark
3-D Image-Based Dosimetry in Radionuclide Therapy
(
- Contribution to journal › Scientific review
-
Mark
Absolute Quantitation of SPECT Studies
(
- Contribution to journal › Article
-
Mark
From fixed activities to personalized treatments in radionuclide therapy : lost in translation?
(
- Contribution to journal › Article
-
Mark
Nuclear medicine : Physics and instrumentation special feature review article: SPECT/CT: An update on technological developments and clinical applications
(
- Contribution to journal › Scientific review
- 2017
-
Mark
Individualised 177Lu-DOTATATE treatment of neuroendocrine tumours based on kidney dosimetry
(
- Contribution to journal › Article
-
Mark
Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification : An IAEA phantom study
(
- Contribution to journal › Article
-
Mark
Comparison of Empiric Versus Dosimetry-Guided Radioiodine Therapy : The Devil Is in the Details
(
- Contribution to journal › Article
-
Mark
Improved scatter correction with factor analysis for planar and SPECT imaging
(
- Contribution to journal › Article
-
Mark
Improved quantitative 90Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling
(
- Contribution to journal › Article
-
Mark
Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector
(
- Contribution to journal › Article
-
Mark
The conflict between treatment optimization and registration of radiopharmaceuticals with fixed activity posology in oncological nuclear medicine therapy
(
- Contribution to journal › Article
- 2016
-
Mark
MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT applied for Dosimetry of Radiopharmaceutical Therapy.
(
- Contribution to journal › Article
-
Mark
Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology
(
- Contribution to journal › Article
-
Mark
Personalized Dosimetry for Radionuclide Therapy Using Molecular Imaging Tools
(
- Contribution to journal › Scientific review
-
Mark
Monte Carlo simulations of the GE discovery alcyone CZT SPECT system
2016) IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2015
-
Mark
Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
(
- Contribution to journal › Article
-
Mark
Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT Systems
(
- Contribution to journal › Article
-
Mark
Hybrid Imaging for Patient-Specific Dosimetry in Radionuclide Therapy
(
- Contribution to journal › Scientific review
-
Mark
Evaluation of inter-departmental variability of ejection fraction and cardiac volumes in myocardial perfusion scintigraphy using simulated data.
(
- Contribution to journal › Article
-
Mark
Using Rose's metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation.
(
- Contribution to journal › Article
-
Mark
Uncertainty propagation for SPECT/CT-based renal dosimetry in (177)Lu peptide receptor radionuclide therapy.
(
- Contribution to journal › Article
-
Mark
Pharmacokinetic digital phantoms for accuracy assessment of image-based dosimetry in (177)Lu-DOTATATE peptide receptor radionuclide therapy.
(
- Contribution to journal › Article
-
Mark
Absorbed Doses and Risk Estimates of (211)At-MX35 F(ab')2 in Intraperitoneal Therapy of Ovarian Cancer Patients.
(
- Contribution to journal › Article
-
Mark
EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision
(
- Contribution to journal › Article
- 2014
-
Mark
Validation of an automated method to quantify stress-induced ischemia and infarction in rest-stress myocardial perfusion SPECT.
(
- Contribution to journal › Article
-
Mark
The accuracy of quantitative parameters in (99m) Tc-MAG3 dynamic renography: a national audit based on virtual image data.
2014) In Clinical Physiology and Functional Imaging(
- Contribution to journal › Article
-
Mark
Quantitative Nuclear Medicine Imaging: Concepts, Requirements and Methods
2014) In Human Health Reports(
- Book/Report › Report
- 2013
-
Mark
MIRD Pamphlet No. 24: Guidelines for Quantitative I-131 SPECT in Dosimetry Applications
(
- Contribution to journal › Article
-
Mark
Dynamic (99m)Tc-MAG3 renography: images for quality control obtained by combining pharmacokinetic modelling, an anthropomorphic computer phantom and Monte Carlo simulated scintillation camera imaging.
(
- Contribution to journal › Article
-
Mark
Application of Monte Carlo Methods to Radionuclide Therapy
2013) p.223-232(
- Chapter in Book/Report/Conference proceeding › Book chapter
- 2012
-
Mark
Patient-Specific Whole-Body Attenuation Correction Maps from a CT System for Conjugate-View-Based Activity Quantification: Method Development and Evaluation.
(
- Contribution to journal › Article
-
Mark
Accuracy and Precision of Radioactivity Quantification in Nuclear Medicine Images
(
- Contribution to journal › Scientific review
-
Mark
Development and evaluation of an improved quantitative Y-90 bremsstrahlung SPECT method
(
- Contribution to journal › Article
-
Mark
Introduction to the Monte Carlo Method
2012) p.1-16(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
The Monte Carlo Method applied in Nuclear Medicine Dosimetry
2012) p.313-321(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Monte Carlo Calculation in Nuclear Medicine: Applications in Diagnostic Imaging - Second Edition
Ljungberg, Michael LU ; Strand, Sven-Erik LU and King, Michael (2012)
- Book/Report › Anthology (editor)
-
Mark
The SIMIND Monte Carlo program
2012) p.111-128(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide Therapy
(
- Contribution to journal › Article
-
Mark
Use of Monte Carlo simulations with a realistic rat phantom for examining the correlation between hematopoietic system response and red marrow absorbed dose in Brown Norway rats undergoing radionuclide therapy with (177)Lu- and (90)Y-BR96 mAbs.
(
- Contribution to journal › Article
-
Mark
En analys av processen för anställning av lärare vid Lunds Universitet sett ur ett genusperspektiv
2012) p.47-56(
- Chapter in Book/Report/Conference proceeding › Book chapter
- 2011
-
Mark
Dosimetry in patients with B-cell lymphoma treated with [90Y]ibritumomab tiuxetan or [131I]tositumomab.
(
- Contribution to journal › Article
-
Mark
Monte Carlo simulations for therapy imaging
2011) International Conference on Image Optimisation in Nuclear Medicine (OptiNM) 317. p.012016-012016(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
The accuracy of absorbed dose estimates in tumours determined by Quantitative SPECT: A Monte Carlo study.
(
- Contribution to journal › Article
-
Mark
Monte Carlo calculations of absorbed doses in tumours using a modified MOBY mouse phantom for pre-clinical dosimetry studies.
(
- Contribution to journal › Article
-
Mark
Image-based patient-specific dosimetry for radionuclide therapy
2011) p.251-265(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Digital billedbehandling
2011)(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Monte Carlo codes in radionuclide therapy
2011) p.116-133(
- Chapter in Book/Report/Conference proceeding › Book chapter
- 2010
-
Mark
90Y Bremsstrahlung Imaging for Absorbed-Dose Assessment in High-Dose Radioimmunotherapy.
(
- Contribution to journal › Article
-
Mark
Dopamine D2 receptor SPECT with I-123-IBZM: evaluation of collimator and post-filtering when using model-based compensation-a Monte Carlo study
(
- Contribution to journal › Article
-
Mark
Lu-177-[DOTA0,Tyr3] Octreotate Therapy in Patients With Disseminated Neuroendocrine Tumors: Analysis of Dosimetry With Impact on Future Therapeutic Strategy
(
- Contribution to journal › Article
-
Mark
Quantitative SPECT imaging
2010)(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Extracorporeal techniques for improving radioimmunotherapy of disseminated malignant tumors
2010)(
- Chapter in Book/Report/Conference proceeding › Book chapter
- 2009
-
Mark
Peptide Receptor Radionuclide Therapy (PRRT) Using 177Lu-DOTATATE: Early Clinical and Dosimetric Results
2009) 6th Annual Conference of the European-Neuroendocrine-Tumor-Society In Neuroendocrinology 90(1). p.44-44(
- Contribution to journal › Published meeting abstract
-
Mark
Evaluation of quantitative planar (90)Y bremsstrahlung whole-body imaging.
(
- Contribution to journal › Article
-
Mark
Registration of serial SPECT/CT images for three-dimensional dosimetry in radionuclide therapy.
(
- Contribution to journal › Article
- 2008
-
Mark
EANM/ESC Guidelines for Radionuclide Imaging of Cardiac function
(
- Contribution to journal › Article
-
Mark
Evaluation of quantitative (90)Y SPECT based on experimental phantom studies.
(
- Contribution to journal › Article
- 2007
-
Mark
Mouse S-factors based on monte carlo simulations in the anatomical realistic Moby phantom for internal dosimetry
(
- Contribution to journal › Article
-
Mark
SIMIND based pinhole imaging: Development and validation
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Optimization of energy-window settings for scatter correction in quantitative In-111 imaging: Comparison of measurements and Monte Carlo simulations
(
- Contribution to journal › Article
- 2006
-
Mark
A model that accounts for the interdependence of extent and severity in the automatic evaluation of myocardial defects.
(
- Contribution to journal › Article
-
Mark
Correction for scatter and septal penetration using convolution subtraction methods and model-based compensation in I-123 brain SPECT imaging - a Monte Carlo study
(
- Contribution to journal › Article
-
Mark
Subendocardial versus transmural ischaemia in myocardial perfusion SPECT - a Monte Carlo study
(
- Contribution to journal › Article
-
Mark
Prompt gamma tomography during BNCT – a feasibility study
(
- Contribution to journal › Article
-
Mark
3-D Monte Carlo-based scatter compensation in quantitative I-131SPECT reconstruction
(
- Contribution to journal › Article
- 2005
-
Mark
Interdependence between measures of extent and severity of myocardial perfusion defects provided by automatic quantification programs.
(
- Contribution to journal › Article
-
Mark
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
(
- Contribution to journal › Article
-
Mark
A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model
(
- Contribution to journal › Article
-
Mark
Comparison of 1- and 2-day protocols for myocardial SPECT: a Monte Carlo study.
(
- Contribution to journal › Article
-
Mark
A new collimator simulation in SIMIND based on the delta-scattering technique
(
- Contribution to journal › Article
-
Mark
Development of educational image databases and e-books for medical physics training
(
- Contribution to journal › Article
-
Mark
Dosimetry Calculations on a Tissue Level by Using the MCNP4c2 Monte Carlo Code.
(
- Contribution to journal › Article
-
Mark
Accurate dosimetry in I-131 radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation
(
- Contribution to journal › Article
-
Mark
The LundADose Method for Planar Image Activity Quantification and Absorbed-Dose Assessment in Radionuclide Therapy.
(
- Contribution to journal › Article
-
Mark
A novel platform for radioimmunotherapy: extracorporeal depletion of biotinylated and (90)y-labeled rituximab in patients with refractory B-cell lymphoma.
(
- Contribution to journal › Article
-
Mark
Evaluation of accuracy in activity calculations for the conjugate view method from monte carlo simulated scintillation camera images using experimental data in an anthropomorphic phantom.
(
- Contribution to journal › Article
-
Mark
A new method to obtain transmission images for planar whole-body activity quantification.
(
- Contribution to journal › Article
-
Mark
European Medical Imaging Technology Training, EMIT – ett prisbelönt EU-utbildningsprojekt
2005) LTHs 3:e Pedagogiska inspirationskonferens, 2005(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2004
-
Mark
A new collimator simulation in SIMIND based on the Delta-Scattering technique
2004) 2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors 6. p.3584-3588(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Evaluation of parameters influencing s values in mouse dosimetry.
(
- Contribution to journal › Article
-
Mark
Absorbed dose distribution in glioma tumors in rat brain after therapeutic intratumoral injection of 201Tl-chloride.
(
- Contribution to journal › Article
-
Mark
Simulation Techniques and Phantoms
2004) p.551-551(
- Chapter in Book/Report/Conference proceeding › Book chapter
- 2003
-
Mark
Calibration of a radioactive ink-based stack phantom and its applications in nuclear medicine.
(
- Contribution to journal › Article
-
Mark
Crypt cell dosimetry for 99Tcm-sestamibi in a new small intestinal dosimetry model.
(
- Contribution to journal › Article
-
Mark
3D absorbed dose calculations based on SPECT: Evaluation for 111-In/90-Y therapy using Monte Carlo simulations.
(
- Contribution to journal › Article
-
Mark
Medical physics e-learning training materials. Information Technology Applications in Biomedicine
2003) 4th Annual IEEE EMBS Special Topic Conf on Information Technology Applications in Biomedicine, ITAB 2003 p.94-97(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
- 2002
-
Mark
A dosimetry model for the small intestine incorporating intestinal wall activity and cross-doses.
(
- Contribution to journal › Article
-
Mark
A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in I-131 SPECT
(
- Contribution to journal › Article
-
Mark
A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy: evaluation for (131)I using monte carlo simulation.
(
- Contribution to journal › Article
-
Mark
Medical Imaging Techniques For Radiation Dosimetry
2002) p.55-79(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Evaluation and validation of dose calculation procedures in patient-specific radionuclide therapy
2002) p.262-281(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
An activity quantification method based on registration of CT and whole-body scintillation camera images, with application to 131I.
(
- Contribution to journal › Article
- 2001
-
Mark
EMERALD training in medical radiation physics
(
- Contribution to journal › Article
-
Mark
Registration of emission and transmission whole-body scintillation-camera images
(
- Contribution to journal › Article
-
Mark
The effect of object shape in SPECT quantification of 131-I tumor activity
(
- Contribution to journal › Article
-
Mark
Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
(
- Contribution to journal › Article
-
Mark
Quantitative Gated SPECT: A Monte Carlo evaluation
(
- Contribution to journal › Letter
-
Mark
Usefulness and pitfalls of planar gamma-scintigraphy for measuring aerosol deposition in the lungs: a Monte Carlo investigation
(
- Contribution to journal › Article
- 2000
-
Mark
Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study
(
- Contribution to journal › Article
-
Mark
Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study
(
- Contribution to journal › Article
-
Mark
Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging
(
- Contribution to journal › Article
-
Mark
Accuracy of 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator: Monte Carlo study
(
- Contribution to journal › Article
- 1999
-
Mark
Radiation dosimetry in nuclear medicine
(
- Contribution to journal › Scientific review
-
Mark
Radioimmunotherapy using 131I-labeled anti-CD22 monoclonal antibody (LL2) in patients with previously treated B-cell lymphomas
(
- Contribution to journal › Article
-
Mark
The influence of backscatter material on 99mTc and 201Tl line source responses
(
- Contribution to journal › Article
-
Mark
A new rectal model for dosimetry applications
(
- Contribution to journal › Article
- 1998
-
Mark
Evaluation of attenuation corrections using Monte Carlo simulated lung SPECT
(
- Contribution to journal › Article
-
Mark
Deformable Fourier surfaces for volume segmentation in SPECT
(
- Chapter in Book/Report/Conference proceeding › Paper in conference proceeding
-
Mark
Introduction to the Monte Carlo Method
1998) p.37-37(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Monte Carlo Calculation in Nuclear Medicine: Applications in Diagnostic Imaging
1998)(
- Book/Report › Book
- 1997
-
Mark
Registration of abdominal CT and SPECT images using Compton scatter data
(
- Chapter in Book/Report/Conference proceeding › Book chapter
-
Mark
Evaluation of optimally designed planar-concave collimators in single-photon emission tomography
(
- Contribution to journal › Article
-
Mark
Selection of collimator for rCBF studies and evaluation of triple-headed SPET using noise-resolution plots
(
- Contribution to journal › Article
- 1996
-
Mark
Segmentation of the Body and Lungs from Compton Scatter and Photopeak Window Images in SPECT: A Monte Carlo Investigation
(
- Contribution to journal › Article
-
Mark
A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents
(
- Contribution to journal › Article
-
Mark
A Monte-Carlo program converting activity distributions to absorbed dose distributions in a radionuclide treatment planning system
(
- Contribution to journal › Article
-
Mark
Parameters influencing volume and activity quantitation in SPECT
(
- Contribution to journal › Article
- 1995
-
Mark
A Monte Carlo investigation of dual-energy-window scatter correction for volume-of-interest quantification in 99Tcm SPECT
(
- Contribution to journal › Article
- 1994
-
Mark
Monte Carlo Simulation of Transmission Studies using a Planar Sources with a Parallel Collimator and a Line Source with a Fan-Beam Collimators
(
- Contribution to journal › Article
-
Mark
Radio-immunotherapy dosimetry with special emphasis on SPECT quantification and extracorporeal immuno-adsorption
(
- Contribution to journal › Scientific review
-
Mark
The Influence of Phantom Size, Shape, and Density, and Collimator Selection on the Dual Photopeak Scatter Correction Method
(
- Contribution to journal › Article
-
Mark
Comparison of four scatter correction methods using Monte Carlo simulated source distributions
(
- Contribution to journal › Article
- 1993
-
Mark
A Monte Carlo Investigation of the Dual Photopeak Window Scatter Correction Method
(
- Contribution to journal › Article
-
Mark
A Scatter Correction Method for 201-Tl images: A Monte Carlo Investigation
(
- Contribution to journal › Article
-
Mark
Radioimmunotherapy dosimetry--a review
(
- Contribution to journal › Scientific review
- 1992
-
Mark
Quantitative single photon emission tomography: verification for sources in an elliptical water phantom
(
- Contribution to journal › Article
- 1991
-
Mark
Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study
(
- Contribution to journal › Article
-
Mark
Quantitative biokinetics study of 111In-labeled F(ab')2 in patients with colorectal cancer
(
- Contribution to journal › Article
- 1990
-
Mark
Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method
(
- Contribution to journal › Article
-
Mark
Comparison of Dual-Window and Convolution Scatter Correction Techniques using the Monte Carlo Method
(
- Contribution to journal › Article
-
Mark
Attenuation correction in SPECT based on transmission studies and Monte Carlo simulations of build-up functions
(
- Contribution to journal › Article
-
Mark
Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions
(
- Contribution to journal › Article
- 1989
-
Mark
A Monte Carlo program for the simulation of scintillation camera characteristics
(
- Contribution to journal › Article
- 1988
-
Mark
Quantitative SPECT in oncological nuclear medicine. Application in Dose Planning for Radionuclide Therapy
(
- Contribution to journal › Scientific review
-
Mark
Dose planning with SPECT
(
- Contribution to journal › Article